If, for any reason, you need to know the pinouts for the modular jacks on the PagePac 6 or PagePac 6
Port Saver, pinout information is given below.

PagePac 6 PAGE Jack

Pin*

Cord Lead†

Function

Connect to Paging Port

1

Not Used

Not Used

Not Used

3

4

5

6

2

Black

Access Control (C)

Dry Contact Closure (C)

Red

Ring

Ring

Green

Tip

Tip

Yellow

Access Control (C1)

Dry Contact Closure (C1)

Not Used

Not Used

Not Used

*Pins numbered from left to right, as seen when looking into jack.
†When using a standard modular cord.
Note: A telephone system paging port dry contact closure is required to connect pins 2 and 5 of
the PAGE jack together to access paging.

PagePac 6 Port Saver C.O. LINE and PHONES Jacks

Pin*

Cord Lead†

Function

Connect to Line Jack

1

2

3

4

5

6

Not Used

Not Used

Not Used

Not Used

Not Used

Not Used

Red

Ring

Ring

Green

Tip

Tip

Not Used

Not Used

Not Used

Not Used

Not Used

Not Used

*Pins numered from left to right, as seen when looking into jack.
†When using a standard modular cord.