Campbell Scientific CS616 and CS625 Water Content Reflectometers User Manual
Page 28

CS616 and CS625 Water Content Reflectometers
Sensor lead
AM16/32
CR10X
CS616-1 green
1H
CS616-2 green
1L
CS616-3 green
2H
CS616-1,2,3 orange
2L
CS616-4 green
3H
CS616-5 green
3L
CS616-6 green
4H
CS616-4,5,6 orange
4L
...
…
CS616-46 green
31H
CS616-47 green
31L
CS616-48 green
32H
CS616-46,47,48
32L
RES
C1
CLK
C2
COM ODD H
SE1
COM ODD L
SE2
COM EVEN H SE3
COM EVEN L
C3
;{CR10X}
;
*Table 1 Program
01: 60
Execution Interval (seconds)
1: Batt Voltage (P10)
;Measure battery voltage
1: 1
Loc [ Bat_Volt ]
2: Internal Temperature (P17) ;Measure datalogger internal temperature
1: 2
Loc [ DL_Temp ]
3: If time is (P92)
;Every 60 Minutes Start Multiplexer Measurement Loop
1: 0
Minutes (Seconds --) into a
2: 60
Interval (same units as above)
3: 11
Set Flag 1 High
4: If Flag/Port (P91)
;User can start Measurement Loop by setting Flag 1 High
1: 11
Do if Flag 1 is High
2: 30
Then Do
5: Do (P86)
;Set control port 1 high (i.e. Reset Multiplexer)
1: 41
Set Port 1 High
6: Beginning of Loop (P87)
;16 loops X 3ea CS616 measured/loop
1: 0
Delay
2: 16
Loop Count
22