Campbell Scientific CS700 Tipping Bucket Rain Gage and CS700H Heated Rain Gage User Manual
Page 21

CS700 and CS700H Rain Gage
Units BattV = Volts
Units CH700HA =inch
Units CH700HB =inch
'Define Data Tables
DataTable(OneMin,True,-1)
DataInterval(0,1,Min,10)
Totalize (1,CH700HA,FP2,False)
Totalize (1,CH700HB,FP2,False)
Sample (1,CS700H_AirTemp,FP2)
Sample (1,CS700H_BlockTemp,FP2)
Sample (1,CS700H_C0_F1,FP2)
Sample (1,CS700H_NoSnow0_Snow1,FP2)
Sample (1,CS700H_SnwSnsrActv,FP2)
Sample (1,CS700H_Htr_On_off,FP2)
Sample (1,CS700H_Control_Auto_Man,FP2)
Sample (1,CS700H_Cycle_Dis_Ena,FP2)
Sample (1,CS700H_LPHTimeLeft,FP2)
EndTable
DataTable(OneDay,True,-1)
DataInterval(0,1440,Min,10)
Minimum(1,BattV,FP2,False,False)
Totalize (1,CH700HA,FP2,False)
'CH700H tipping bucket a
Totalize (1,CH700HB,FP2,False)
'CH700H tipping bucket b
EndTable
'Main Program
BeginProg
Scan(5,Sec,1,0)
'Default Datalogger Battery Voltage measurement BattV
PanelTemp (PTemp,_60Hz)
Battery(BattV)
'SDI-12 Sensor measurements
SDI12Recorder(Info(),1,"0","M!",1,0)
'CS700H Rain Gauge measurement Rain_in
PulseCount(CH700HA,1,12,2,0,0.01,0)
'CS700H Rain Gauge measurement Rain_in
PulseCount(CH700HB,1,13,2,0,0.01,0)
'Call Data Tables and Store Data
CallTable(OneMin)
CallTable(OneDay)
NextScan
EndProg
17