Campbell Scientific CS700 Tipping Bucket Rain Gage and CS700H Heated Rain Gage User Manual

Page 21

Advertising
background image

CS700 and CS700H Rain Gage

Units BattV = Volts

Units CH700HA =inch

Units CH700HB =inch

'Define Data Tables

DataTable(OneMin,True,-1)

DataInterval(0,1,Min,10)

Totalize (1,CH700HA,FP2,False)

Totalize (1,CH700HB,FP2,False)

Sample (1,CS700H_AirTemp,FP2)

Sample (1,CS700H_BlockTemp,FP2)

Sample (1,CS700H_C0_F1,FP2)

Sample (1,CS700H_NoSnow0_Snow1,FP2)

Sample (1,CS700H_SnwSnsrActv,FP2)

Sample (1,CS700H_Htr_On_off,FP2)

Sample (1,CS700H_Control_Auto_Man,FP2)

Sample (1,CS700H_Cycle_Dis_Ena,FP2)

Sample (1,CS700H_LPHTimeLeft,FP2)

EndTable

DataTable(OneDay,True,-1)

DataInterval(0,1440,Min,10)

Minimum(1,BattV,FP2,False,False)

Totalize (1,CH700HA,FP2,False)

'CH700H tipping bucket a

Totalize (1,CH700HB,FP2,False)

'CH700H tipping bucket b

EndTable

'Main Program

BeginProg

Scan(5,Sec,1,0)

'Default Datalogger Battery Voltage measurement BattV

PanelTemp (PTemp,_60Hz)

Battery(BattV)

'SDI-12 Sensor measurements

SDI12Recorder(Info(),1,"0","M!",1,0)

'CS700H Rain Gauge measurement Rain_in

PulseCount(CH700HA,1,12,2,0,0.01,0)

'CS700H Rain Gauge measurement Rain_in

PulseCount(CH700HB,1,13,2,0,0.01,0)

'Call Data Tables and Store Data

CallTable(OneMin)

CallTable(OneDay)

NextScan

EndProg