Campbell Scientific ENC10/12, ENC12/14, ENC14/16, ENC16/18 Enclosures User Manual
Page 35

Appendix A. Door Switch
9: End (P95)
10: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 5
Interval (same units as above)
3: 10
Set Output Flag High (Flag 0)
11: Set Active Storage Area (P80)
1: 1
Final
Storage
Area
1
2: 101
Array
ID
12: Sample (P70)
1: 1
Reps
2: 2
Loc [ DOOR_out ]
; Reset door status after output interval
13: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 5
Interval (same units as above)
3: 30
Then
Do
14: Z=F x 10^n (P30)
1: 0.0
F
2: 00
n,
Exponent
of
10
3: 2
Z Loc [ DOOR_out ]
15: End (P95)
; Method #2 ==================================
16: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 5
Interval (same units as above)
3: 10
Set Output Flag High (Flag 0)
17: Set Active Storage Area (P80)
1: 1
Final
Storage
Area
1
2: 102
Array
ID
18: Histogram (P75)
1: 1
Reps
2: 1
No.
of
Bins
3: 1
Closed
Form
4: 1
Bin Select Value Loc [ DOORopen1 ]
5: 0
Frequency
Distribution
6: 0.5
Low
Limit
7: 1.5
High
Limit
*Table 2 Program
02: 0
Execution
Interval
(seconds)
*Table 3 Subroutines
End Program
A-7