Model HFP01 Soil Heat Flux Plate

6.2 Wiring

Connections to Campbell Scientific dataloggers are given in Table 6-1 and
Figure 6-2. The output of the HF01 can be measured using a single-ended
analog measurement (VoltSE() in CRBasic or Instruction 1 in Edlog) or a
differential analog measurement (VoltDiff() in CRBasic or Instruction 2 in
Edlog).

TABLE 6-1. Datalogger Connections for a

Single-Ended Measurement



Description



Color


CR10(X), CR510,

CR500

CR800, CR850,

CR1000, CR3000,

CR5000, CR23X,

21X, CR7,

Signal

White

Single-Ended Input

Single-Ended Input

Signal Reference

Green

AG

Shield Clear

G

6.3 Programming

To calculate the calibration multiplier, divide 1000 by the nominal calibration
sensitivity (i.e., 1000/sensitivity). The nominal calibration sensitivity is unique
for each HFP01. Each sensor is accompanied with a calibration certificate and
has a label on it with the calibration values. The label is located on the pigtail
end of the sensor leads.

In example 1, the nominal calibration sensitivity is 67.1

μV/W

-2

for the

HFP01#1 and 67.0

μV/W

-2

for the HFP01#2. In examples 2 and 3, the

nominal calibration sensitivity is 67.1

μV/W

-2

.

TABLE 6-2. Wiring for Example 1

Description

Color

CR3000

Sensor Signal #1

White

7H

Sensor Signal Reference #1

Green

7L

Shield #1

Clear

Sensor Signal #2

White

8H

Sensor Signal Reference #2

Green

8L

Shield #2

Clear