Specifications – Campbell Scientific HMP60 Temperature and Relative Humidity Probe User Manual
Page 14

HMP60 Temperature and Relative Humidity Probe
TABLE 5-1. Recommended Lead Lengths
2 m Height
Atop a tripod or tower via a 2 ft crossarm such as the CM202
Mast/Leg CM202 CM6
CM10
CM110
CM115
CM120
UT10
UT20
UT30
9' 11'
11'
14'
14'
19'
24'
14'
24'
37'
Note: Add two feet to the cable length if you are mounting the enclosure on the leg base of a light-weight tripod.
The probe’s cable can terminate in:
• Pigtails that connect directly to a Campbell Scientific datalogger
(option –PT).
• Connector that attaches to a prewired enclosure (option –PW). Refer
for more information.
• Connector that attaches to a CWS900 Wireless Sensor Interface
(option –CWS). The CWS900 allows the probe to be used in a
wireless sensor network. Refer to
for
more information.
• Connector that attaches to a CS110 Electric Field Meter or an ET-
series weather station (option –C). Refer to
for more information.
6. Specifications
Features:
• Field -replaceable humidity chip eliminates recalibration down time
• Compatible with all Campbell Scientific dataloggers (including the
CR200(X) series)
• Compatible with the CWS900-series interfaces, allowing it to be used
in a wireless sensor network
Compatibility
Dataloggers:
CR200(X) series
CR800 series
CR1000
CR3000
CR5000
CR9000(X)
CR7X
CR510
CR10(X)
CR23X
21X
Operating Temperature: -40
° to +60°C
Probe Length:
7.1 cm (2.8 in)