Section 9. Datalogger Program Creation with CRBasic Editor

The Constant Customization syntax may be best understood by looking at an
example. Consider the following program code:

'Start of Constants Customization Section
Const SInterval=10
‘Min=5
‘Max=60
‘Inc=5

Const SUnits = sec
'value=sec
'value=min

Const Reps=1

Const Number=0
'Min=-100
'Max=100

Const TableName="OneSec"
'value="OneMin"
'value="OneHour"
'value="OneDay"

'End of Constants Customization Section


This code will create the following constant customization dialog box: