Raven110 GPRS/EDGE AirLink Cellular Modem

Verify the APN has been entered in the NETAPN and +CGDCONT fields as
shown above (where gprs02.Motient.net is the APN).

7.2 Verify Connections at the Datalogger

Verify the modem is connected to 12 V and the Pwr led is on (green).

Check the Reg light on the modem. The Reg light should be solid green,
which indicates the modem is registered with the cellular network.

Make sure the antenna is properly connected and oriented. Signal strength
should be the -60 to -80.

An SC932A or SC105 interface is required to connect the modem to a
datalogger’s CSI/O port. The default settings for SC105 can be used with the
Raven110 when the modem is configured for 9600 baud (baud rate set by the
template file). If the baud rate is changed in the modem, the baud rate in the
SC105 will have to be changed to match that of the modem (SC105 settings
can be changed using CSI’s DevConfig utility).

Make sure the modem is connected to the “DCE Device” connector on the
SC932A, or the “Modem” connector on the SC105.

A null modem cable is required to connect the modem to a datalogger’s
RS-232 port. No other interface is required.

7.3 LoggerNet/PC400W Device Map

The IP address and Device Port settings are entered in LoggerNet as described
in Section 6.

Make sure the port number at the end of the IP address matches the port
number of the modem. The template file sets the port number to 3001.