RF401A-Series Spread Spectrum Radio

11.3.3 Radio Firmware Version

Radio firmware version

11.3.4 Received Signal Strength

This setting provides a means of knowing the signal strength of the last packet

received that was addressed to this radio and that had a valid CRC.

The RSS reading is a relative signal level indication expressed in dB (decibels).

Readings may vary up to 10 dB from radio to radio for a given received signal

level. The weakest signal reading is around 25 dB and the strongest signal

reading is near 86 dB. Although the RSS readings are not absolute, they will

be of value in such activities as:

determining the optimal direction to aim a Yagi antenna

determining the effects of antenna height, location

trying alternate (reflective) paths

seeing the effect of seasonal tree leaves

11.3.5 Retransmit Failures

Records the number of retransmit failure.

11.3.6 ME Baud Rate

Specifies the baud rate that will be used on the CSI/O port when configured for

ME Master.

11.3.7 RS-232 Parity

Specifies the parity that will be used on the RS-232 port.

11.3.8 RS-232 Stop Bits

Specifies the number of stop bits used on the RS-232 port.

11.3.9 RS-232 Character Length

Specifies the length in bits of character frames on the RS-232 port.

11.3.10 RS-232 Auto Power Down

Specifies whether to always power the RS-232 device or that the RS-232 TX

automatically powers down when there is no activity for 30 seconds.

11.3.11 AT Sequence Character

Specifies the character that should be sent three times sequentially in order to

put the modem in “local” mode.

11.3.12 Silence Time Before Command Sequence

Specifies the amount of time (in tenths of seconds) that the RS-232 interface

must be silent after accepting the AT command sequence before the RF401A

series will enter command mode.

24