Supported commands, Sdi-12 commands supported – Campbell Scientific Sentek EnviroSCAN EasyAG SDI-12 Manual v 3.4 User Manual
Page 20
EnviroSMART & EasyAG SDI-12 Probe Manual
Copyright © 1991 – 2003 Sentek Pty Ltd All rights reserved
Page 15
Supported Commands
SDI-12 Commands Supported
The following commands are supported by the EnviroSMART and EasyAG SDI-12 probe interfaces:
Command
Name
Response
a!
Acknowledge 
Active 
a<CR><LF> 
The probe interface address 
aI!
Send 
Identification 
allccccccccmmmmmmvvvxxxxxxxxxxxx<CR><LF> 
Identification information 
aAb!
Change Address
a<CR><LF> 
The probe interface address 
aM!
Start 
Measurement 
atttn<CR><LF> 
Delay (ttt) in seconds and number of 
values (n) up to 9 
aMn!
Start 
Measurement 
n in range “1” 
- “3” 
atttn<CR><LF> 
Delay (ttt) in seconds and number of 
values (n) up to 9 
Note: A response of a0000<CR><LF> is 
provided indicating all values are 
served by previous Start Measurement 
commands (aMn!) 
aC!
Concurrent 
Measurement 
atttnn<CR><LF> 
Delay (ttt) and number of values (nn) up 
to 16 
aCn!
Concurrent 
Measurement 
n in range “1” 
- “9” 
atttnn<CR><LF> 
Delay (ttt) and number of values (nn) up 
to 16 
Note: A response of a0000<CR><LF> is 
provided indicating all values are 
served by previous Start Concurrent 
Measurement (aCn!) commands 
aDn!
Send Data 
n in range “0” 
- “9” 
Refer to “Data Reading” section
aV!
Start 
verification 
a0000<CR><LF>
aRn!
Continuous 
Measurement 
a<CR><LF> 
Not supported 
Probe interface will respond with its 
address