Campbell Scientific SI-111 (IRR-P) Precision Infrared Radiometer User Manual
Page 14

SI-111 Precision Infrared Radiometer
;Target temperature calculation based on m and b coefficients.
15: Z=F x 10^n (P30)
1: 0.4
F
2: 1
n,
Exponent
of
10
3: 14
Z Loc [ Exponent1 ]
16: Z=F x 10^n (P30)
1: 0.025
F
2: 1
n,
Exponent
of
10
3: 15
Z Loc [ Exponent2 ]
17: Z=X^Y (P47)
1: 8
X Loc [ SB_Temp_K ]
2: 14
Y Loc [ Exponent1 ]
3: 16
Z Loc [ 1_SB_4Pow ]
18: Z=X*Y (P36)
1: 11
X Loc [ mV_tpile ]
2: 12
Y Loc [ m_slope ]
3: 17
Z Loc [ 2_mVxm ]
19: Z=X+Y (P33)
1: 16
X
Loc
[
1_SB_4Pow
]
2: 17
Y
Loc
[
2_mVxm
]
3: 18
Z Loc [ 3_Sum1 ]
20: Z=X+Y (P33)
1: 13
X
Loc
[
b_inter
]
2: 18
Y
Loc
[
3_Sum1
]
3: 19
Z Loc [ 4_Sum2 ]
21: Z=X^Y (P47)
1: 19
X
Loc
[
4_Sum2
]
2: 15
Y Loc [ Exponent2 ]
3: 20
Z Loc [ T_Temp_K ]
22: Z=X+F (P34)
1: 20
X Loc [ T_Temp_K ]
2: -273.15 F
3: 21
Z Loc [T_Temp_C ]
;Output average values once an hour
23: If time is (P92)
1: 0
Minutes (seconds -- ) into a
2: 60
Interval (same units as above)
3: 10
Set Output Flag High (Flag 0)
24: Real Time (P77)
1: 1220
Year, Day, Hour/Minute (midnight = 2400)
25: Average (P71)
1: 1
Reps
2: 21
Loc
[
T_Temp_C
]
8