3 cr10x control port example – Campbell Scientific TB4 and TB4MM Hydrological Services Rain Gage User Manual
Page 13
TB4 and TB4MM Rain Gage
'Main Program
BeginProg
Scan
(1,Sec)
'TB4 Rain Gage measurement Rain-mm
PulseCount
(Rain_mm,C2,2,0,.254,0)
; Black wire connected to C2
'Call Data Tables and Store Data
CallTable
(Rain)
NextScan
EndProg
5.2.3 CR10X Control Port Example
Although this program is for the CR10X datalogger, our CR500, CR510, and
CR23X are programmed similarly.
;{CR10X}
*Table 1 Program
01: 1.0000 Execution
Interval
(seconds)
1: Pulse (P3)
1: 1
Reps
2: 8
Control Port 8 (switch closure only) ;Black wire connect to C8
3: 2
Switch Closure, All Counts
4: 1
Loc [ Rain_mm ]
5: .254
Multiplier
6: 0
Offset
2: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 60
Interval (same units as above)
3: 10
Set Output Flag High (Flag 0)
3: Set Active Storage Area (P80)
1: 1
Final Storage Area 1
2: 101
Array
ID
4: Real Time (P77)
1: 1220
Year,Day,Hour/Minute (midnight = 2400)
5: Sample (P70)
1: 1
Reps
2: 1
Loc [ Rain_mm ]
*Table 2 Program
01: 0.0000 Execution
Interval
(seconds)
*Table 3 Subroutines
End Program