Section 4. Vosponder Configuration and Programming

4-8

M – SDI-12 Mode

. The SDI-12 mode can be set to master or slave .

The unit defaults to “Slave” mode. In the slave mode the unit emulates a
sensor. In the master mode the unit emulates a datalogger. For CSI datalogger
users, it is recommended that the Vosponder be in the “Slave” mode. See
Appendix A for more information on why and how to use the “Master” mode.

E:>M
EM>

(M)aster
(S)lave
(ESC)
EM>S

T – x (Transmit)

. The transmit settings below should not require

modification under normal conditions. This command allows the user to
modify radio transmit interval, delay, hang time and channel busy sense
settings.

E:>T
E:>
ET>
ET>TX Int:0 TX Dly:500 TX Hang:700 RCOS TX:N

TX Int:0
ET>TX Dly:500
ET>TX Hang:700

TX on COS Y/I/N/D:N
ET>

• The Transmit Interval is set in seconds from 0 to 65535 seconds. {default

= 0}

o

This value is used to determine the time between transmission of the
last data stored in the unit from the datalogger in the slave mode or the
interval between issuing a sensor query and transmitting the data
retrieved from the sensor(s).

o

The interval timer (not the time value) is reset upon DTMF or RCOS
query.

o

The keyboard characters entered here are not echoed to the PC
terminal until an <ENTER> key has been pressed.

• The Transmit Delay is set in milliseconds from 0 to 65535. {default =

500}

o

This parameter determines the delay time before the Vosponder starts
speaking after it keys the transmitter push-to-talk.

o

The keyboard characters entered here are not echoed to the PC
terminal until an <ENTER> key has been pressed.