Operating, Instructions, Warning – Wesley BC-6200-8SA User Manual

Page 13

Advertising
background image

13

Owner’s Manual and Service Guide – BCG Series

WARNING

OPERATING

INSTRUCTIONS

To

prevent

unexpected

vehicle

movement

or

unauthorized use, always turn the key switch to the OFF
position and remove key when the vehicle is not in use

Programmable Security Switch (Optional): SAFE-T-
LOCK™ is a programmable code switch,( Figure 4), which
prevents unauthorized use of the vehicle. It is offered as an

option, part number EV-
E901. The SAFE-T-LOCK
switch is installed in lieu of
the standard switch to
control access and
operation of the vehicle
within the c

ustomer’s

premises. It can be pre-
installed at time of order, or
purchased separately to
upgrade existing vehicles.

The STL1000 switch allows

plant and facility managers

to input up to 99 different users/drivers to track vehicle
usage. If an accident occurs, or the vehicle is damaged, the
manager can easily identify the last operator. The switch
also features an internal clock that records "on" hours and
notifies the operator when the 250-hour mark is reached.

Each user can select a four- to eight-digit personal access
code and a separate supervisor user menu programs the
unit. The switch will provide the last user ID code when
prompted by the supervisor. In operation, only users with
active ID codes can operate the vehicle, virtually eliminating
all unauthorized use, the company said.

The switch operates in a voltage range from 9 to 120 volts
DC and is enclosed in an IP65 rated housing. Two internal
LEDs indicate operational status - red indicates an error or
lock mode and green indicates key press or touch is active.
The unit also provides user feedback with key beep and
error tones.

Step-by-Step Programming Instructions:
1

– Log onto the Supervisor Mode. Press 0 0 1 2 3 4

ENTER. Red and Green LED flashes along with an up tone
beep indicate you are in the Supervisor Mode and ready to
enter a Supervisor Mode menu.

Note: As you enter each Supervisor Mode menu, the number
of Red LED flashes will correspond to the menu number. For
example, one Red LED flash for menu 1, two Red LED
flashes for menu 2, etc.

Before changing the Supervisor PIN, you are first going to
add User locations. For this example you will check on and
add User location 01 as well as more User locations as
required. To do this you must go into the Add / Delete User
Menu.


2

– Go into Add / Delete User Menu. Press 2 ENTER. There

will be a beep along with two Red LED flashes indicating you
are in Menu 2. Press 0 1 ENTER. If there is a Red flash and
a low beep, it indicates that user location 01 has already
been assigned. To remove location 01, press ENTER again.
This will delete the location from use.

Add location 01. Press 0 1 ENTER. You should now get a
Green flash along with an up tone beep indicating the
location is ready to be added or assigned to a user. Press
ENTER. You will get a Green LED flash along with a beep.
The user location has been added.

At this point you can, in the same way, check on and add
more user locations.

Before leaving Menu 2, check to make sure that location 01
and any others have been added. Press 0 1 ENTER. There
should be a Red LED flash along with a low tone beep
indicating the location has been assigned to the user. Check
any other locations you’ve added the same way. A Red flash
along with a low tone beep means the location has been
assigned. A Green flash along with an up tone beep means
the location is not assigned.

3

– Go out of Menu 2. Press CE. The switch will indicate you

are back in Supervisor Mode. Press CE again to go out of
Supervisor Mode. (CE can be pressed several times to make
sure you are completely clear and ready to enter the next
mode.)

4

– Log onto the User Mode. Press 0 1 1 2 3 4 ENTER. The

switch will close and the Green LED will flash at a slow rate.

5

– Change User PIN. First decide on a new PIN. In this

example
e use 5 4 3 2 1. Press 1, ENTER. (This puts you in the
Change User PIN Menu.) Note that the switch will open
when you go into this menu.

Note: The User has 1 minute after logging on the User Mode
to use menu 1 before the menu function is locked out until
the next User log on.

Press 5 4 3 2 1 ENTER, again press 5 4 3 2 1 ENTER. The
switch will indicate that the new PIN has been accepted.

6

– Use the new PIN to close the switch. Press 0 1 5 4 3 2 1

ENTER. The switch will close. Press ENTER to open the
switch and go out of User Mode. (Since this is an example,
you may want to set the PIN for User location 01 back to the
1 2 3 4 default.)

7

– Log back onto the Supervisor Mode to change the

Supervisor PIN. Press 0 0 1 2 3 4 ENTER. Press 1 ENTER
to go into the Change Supervisor PIN Menu. The red LED
will flash once. Now just you did in the User Mode, put the
new PIN in twice and enter each time. Example: Press 5 4 3
2 1 ENTER, again 5 4 3 2 1 ENTER. The switch will give an
indication that the PIN was changed.

F

IGURE

4

Advertising