Unit connectors

Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet. Using shielded
cables is recommended.

Power connector - Mini DC connector. 5.1V DC, max 4.0W. See product label for

±

connection.

Audio in - 3.5mm input for a mono microphone, or a line-in mono signal (left channel is used from
a stereo signal).

Audio out - Audio output (line level) that can be connected to a public address (PA) system or an
active speaker with a built-in amplifier. A pair of headphones can also be attached. A stereo
connector must be used for the audio out.

I/O terminal connector - Used in applications for e.g. motion detection,
event triggering, time lapse recording and alarm notifications. It provides the
interface to:

• 1 transistor output - For connecting external devices such as relays and LEDs. Connected

devices can be activated by the VAPIX Application Programming Interface (API), by the out-
put buttons on the

Live View page or by an Event Type. The output will show as active

(shown under

Event Configuration > Port Status) if the alarm device is activated.

• 1 digital input - An alarm input for connecting devices that can toggle between an open

and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc.
When a signal is received the

state changes and the input becomes active (shown under

Event Configuration > Port Status).

• Auxiliary power and GND

Function

Pin

Notes

Specifications

GND

1

Ground

3.3V DC
Power

2

Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.

Max. load = 50mA

Digital
Input

3

Connect to GND to activate, or leave floating
(or unconnected) to deactivate.

Min. input= - 40V DC
Max. input= + 40V DC

Digital
Output

4

Uses an open-drain NFET transistor with the
source connected to GND. If used with an
external relay, a diode must be connected in
parallel with the load, for protection against
voltage transients.

Max. load = 100mA
Max voltage = + 40V DC