Controls configuration & adjustments, Microprocessor factory default settings, Microprocessor level-2 set up & calibration codes – Aquacal Heat Pump User Manual

Page 51: Level –1 and level-2 default settings, Service adjustable parameters

Advertising
background image

51

Controls Configuration & Adjustments...

Microprocessor Factory Default Settings

Level –1 and Level-2 Default Settings

Microprocessor Level-2 Set Up & Calibration Codes

Service Adjustable Parameters

Code Description Factory

Setting

Range

[LOC]

Service Lock Code

50

00-99

[dEL]

4-minute Delay on Make

1

0 / 1

[JAO]

External Controller Interface

0

0 / 2 / 3

[FS2]

Flow Switch/Auto T-Stat Switching

0

0 / 1

[tSC]

Water Sensor Calibration

Factory Calibrated

+10

o

to –10

o

of display

[dSC]

Defrost Sensor Calibration

Factory Calibrated

+10

o

to –10

o

of display

[dBS]

Spa Dead Band Differential

1

o

1

o

to 5

o

[dBP]

Pool Dead Band Differential

1

o

1

o

to 5

o

Menu Code

Description

Default

Value

Range

Level-1

[CF1]

Celsius/Fahrenheit

1

0 / 1

Level-1

[ULC]

User Lock Code

0

0 / 1

Level-1 [ELC]

Enter

Lock

Code

0

00-99

Level-1

[CFO]

Call / Flex

0

0 / 1 / 2

Level-1 [LOC]

Service

Lock

Code

50

00-99

Mode Key

Pad

Operating

Mode

OFF

For Heat Only: OFF/HEAT

For Heat & Cool:

OFF, HEA, COO, ACH

Thermostat

Key Pad

Thermostat Settings Pool & Spa

OFF

45

o

F – 104

o

F

Level-2 [dEL]

Anti-Short Cycle, 4-minute Delay

on Make

1

0 / 1

Level-2

[JAO]

External Controller Interface

0

0 / 2 / 3

Level-2 [FS2]

Flow Switch / Automatic

Thermostat Switching

0

0 / 1

Level-2

[tSC]

Water Sensor Calibration

Factory Calibrated

+10

o

to –10

o

of displayed

value

Level-2

[dSC]

Defrost Sensor Calibration

Factory Calibrated

+10

o

to –10

o

of displayed

value

Level-2

[dBS]

Spa Dead Band Differential

1

o

1

o

to 5

o

Level-2

[dBP]

Pool Dead Band Differential

1

o

1

o

to 5

o

Advertising