Instructions for the installer



12.7 Gas

regulations

If the cooking appliance is set up for a different type of gas than that available, its injectors must
be replaced, the minimum flow regulated. In order to replace the injectors in the cooking hob, it is
necessary to carry out the following operations:

• remove the pan supports;

• remove the burners and burner caps (Fig. A);

• take out the injector (Fig. B) and replace it with one

suitable for the new type of gas (see "G

ENERAL

INJECTORS TABLE

");

• replace the gas label (on the rear of the appliance) with

the new one provided with the injectors kit;

• refit all parts by following the disassembly instructions in

reverse order and taking care to position the burner cap
correctly on the burner.

12.7.1 Minimum flow of valved cooking hob taps

• Switch on the burner and turn the control knob

towards the minimum flow position ;

• remove the knob;

• using a screwdriver, adjust the internal screw Z

until the correct low flame is obtained;

• refit the knob.

12.7.2 Minimum flow of non-valved cooking hob taps

• Switch on the burner and turn the control knob

towards the minimum flow position ;

• remove the knob;

• insert a small screwdriver into the rod of the tap

and adjust the internal screw Z until the correct
low flame is obtained;

• refit the knob.

Unscrew the adjustment screw Z to increase the flow, or tighten it to reduce the flow.

The adjustment is correct when the low flame measures approximately 3 or 4 mm.

When changing quickly from maximum to minimum flow and vice versa make sure that the

flame does not go out.

GENERAL INJECTORS TABLE

POWER Watt

CONSUMPTION

TYPE OF GAS

mBar

NOZZLE NO.

BURNERS

POSITION TYPE

MAX.

MIN.

MAX.

115

RAPID

3000

750

286 l/h

97

SEMI RAPID

1750

480

167 l/h

72

AUXILIARY

1000

330

95 l/h

128

TRIPLE-RING

3300

1300

314 l/h

NATURAL GAS

20

94

FISH KETTLE

1900

750

181 l/h

85

RAPID

3000

750

219 g/h

65

SEMI RAPID

1750

480

128 g/h

50

AUXILIARY

1000

330

73 g/h

93

TRIPLE-RING

3300

1300

241 g/h

LPG

BUTANE

PROPANE

30
28
37

68

FISH KETTLE

1900

750

138 g/h

12.8 Connecting

to

LPG

Use a pressure regulator and connect to the cylinder in compliance with the guidelines set out in
standards regulations in force.
Note: L.P.G. cookers MUST NOT be installed below ground level i.e. in a basement or aboard

any

boat, yacht or other vessel.