Installation, Table 2 – Alliance Laundry Systems T433I User Manual

Page 28

Advertising
background image

Installation

M414038

26

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Model 120FG

INPUT: 87.8 kW

Table 2

NOTE: In addition to directions below, follow all
instructions including verification and adjustment
of injector pressure.

1 – Order as Regulated Natural Gas. No modification
needed.

2 – Order as Regulated Natural Gas. Apply
appropriate country sticker.

3 – Order as Regulated Natural Gas. Apply
appropriate country and gas stickers.

4 – Order as Unregulated with Unregulated Natural
Gas injectors. Apply appropriate country sticker.

5 – Order as Unregulated with L.P. Gas injectors.
Apply appropriate country sticker.

6 – Order as Regulated Natural Gas. Convert with
(3) 2.6 mm injectors Part No. M411376. Apply
appropriate country and gas stickers.

7 – Order as Unregulated with L.P. Gas injectors. No
modification needed.

8 – Order as Unregulated with L.P. Gas injectors.
Apply appropriate country sticker.

OPEN – No Approval available.

Special Cases – No additional kits are required to
convert from regulated to unregulated.

Gas

Type

GB

IE

PT

ES

IT

DK

NO

SE

FI

DE

NL

BE

FR

AT

Gas

Family

& Group

Inject. 0

Inject. Qty

& Part. No.

Inlet

Press.

Gvnr./

Regltr.

Inject.

Press.

Nat.

Gas

1

1

1

1

1

2

2

2

2

2

2

2nd

family

Group H

(E)

4.8 mm

3

M411372

20 mbar

Yes

8.9 mbar

3

2nd

family

Group L

(LL)

4.8 mm

3

M411372

25 mbar

Yes

12.0

mbar

4

4

2nd

family

Group E+

4.2 mm

3

M402295

20.25

mbar

No

Unreg.

L.P.
Gas

5

5

5

5

5

5

3rd

family
Group

B/P

2.6 mm

3

M411376

30 mbar

No

Unreg.

6

6

3rd

family
Group

B/P

2.6 mm

3

M411376

50 mbar

Yes

26.4

mbar

7

7

7

7

7

8

8

3rd

family

Group 3+

2.6 mm

3

M411376

28.37

mbar

No

Unreg.

Advertising