EtherHub-16 Quick Start Guide

8

You may find the following book prepared by the Federal Communication Commision helpful:

The Interference Handbook

This booklet is available from the U.S. Government Printing Office. Washington, D.C. 20402.
Stock No. 004-000-00345-4.

Safety Compliance

Underwriters Laboratories Compliance Statement

Important! Before making connections, make sure you have the correct Cord Set. Check it (read
the label on the cable) against the following specification list.

Operating

Voltage

Cord Set Specifications

120 Volts

UL Listed/CSA Certified Cord Set
Minimum 18 AWG
Type SVT or SJT three conductor cord
Maximum length of 15 feet
Parallel blade, grounding type attachment plug rated 15A, 125V

240 Volts (For

UL Listed/CSA Certified Cord Set

North America)

Minimum 18 AWG
Type SVT or SJT three conductor cord
Maximum length of 15 feet
Tandem blade, grounding type attachment plug rated 15A, 125V

240 Volts (For

Cord Set with H05VV-F cord having three conductors with minimum diameter of 0.75 mm

2

Europe only)

IEC-320 receptacle
Male plug rated 6A, 250V

The unit automatically matches the connected input voltage. Therefore, no additional adjustments
are necessary when connecting it to any input voltage within the range marked on the rear panel.

Do not plug a phone jack connector into any of the RJ-45 ports.
This may damage the hub.