background image

Appendix B

I/O Interface Board

CoreModule 800

QuickStart Guide

29

Table B-5 lists the connections on the I/O Board between Serial Port 2 connector (J7A) and the
Utility 1a interface connector (J4) or other connections on the board.

Table B-5. Serial Port 2 (COM2) Interface Pin/Signal Descriptions (J7A)

J7A
Pin #

(DB9)

Signal

From
Onboard
Connector
& Pin #

Description

1

DCD2*

J4-11

Data Carrier Detect 2 – Indicates external serial device is detecting a
carrier signal (i.e., a communication channel is currently open). In
direct connect environments, this input is driven by DTR2 as part of
the DTR2/DSR2 handshake.

2

RXD2

J4-13

Receive Data 2 Input – This line is typically held at a logic 1 (mark)
when no data is being transmitted, and is held “Off” for a brief
interval after an “On” to “Off” transition on the RTS2 line to allow
the transmission to complete.

3

TXD2

TTL

JP1-2

(J4-15, or

J4-20)

Serial Transmit Data 2 Output – The signal on this line comes from
J4-15 or J4-20 thorough the only jumper (JP1) on the I/O Interface
Board.
TXD2 signal – This signal (J4-15) is available if jumper JP1 on the
I/O Board is set to pins 1-2 (default setting). This line (TXD2) is
typically held to a logic 1 when no data is being sent. Typically, a
logic 0 (On) must be present on RTS1, CTS1, DSR1, and DTR1
before data can be transmitted on this line.
TTL signal – This signal (J4-20) is available if jumper JP1 on the
I/O Board is set to pins 2-3.

4

DTR2*

J4-17

Data Terminal Ready 2 – Indicates port is powered, initialized, and
ready. Used as hardware handshake with DSR2 for overall readiness.

5

GND

J4-19

Ground

6

DSR2*

J4-12

Data Set Ready 2 – Indicates external serial device is powered,
initialized, and ready. Used as hardware handshake with DTR2 for
overall readiness to communicate.

7

RTS2*

J4-14

Request To Send 2 – Indicates serial port is ready to transmit data.
Used as hardware handshake with CTS2 for low level flow control.

8

CTS2*

J4-16

Clear To Send 2 – Indicates external serial device is ready to receive
data. Used as hardware handshake with RTS2 for low level flow
control.

9

RI2*

J4-18

Ring Indicator 2 – Indicates external serial device is detecting a ring
condition. Used by software to initiate operations to answer and
open the communications channel.

Notes: The shaded area denotes power or ground. The signals marked with * = Negative true logic.