Site master pm 69 – Anritsu Site Master S331D User Manual

Page 75

Advertising
background image

316) Impedance Loss

247

(higher byte)

317) Impedance Loss (lower byte)

318) Frequency Scale Factor

248

(higher byte)

319) Frequency Scale Factor (lower byte)

320) Frequency Range Minimum

249

(highest byte)

321) Frequency Range Minimum

322) Frequency Range Minimum

323) Frequency Range Minimum (lowest byte)

324) Frequency Range Maximum

250

(highest byte)

325) Frequency Range Maximum

326) Frequency Range Maximum

327) Frequency Range Maximum (lowest byte)

328) Linked Trace Number (1-200)

329) Status Byte 9 (0b=Off, 1b=On)

(LSB)

bit 0 : C/I Measurement On/Off

bits 1-3 : C/I Carrier Trace/Signal Type

251

bits 4-7 : Not Used

330) C/I Calculated Power

252

(Carrier or Interference - NB FHSS

253

) (highest byte)

331) C/I Calculated Power (Carrier or Interference - NB FHSS) (lowest byte)

332) C/I Calculated Power (Carrier or Interference - NB FHSS) (highest byte)

333) C/I Calculated Power (Carrier or Interference - NB FHSS) (lowest byte)

334) C/I Calculated Power

254

(Interference - WB FHSS

255

) (highest byte)

335) C/I Calculated Power (Interference - WB FHSS) (lowest byte)

336) C/I Calculated Power (Interference - WB FHSS) (highest byte)

337) C/I Calculated Power (Interference - WB FHSS) (lowest byte)

338) C/I Calculated Power

256

(Interference - Broadband

257

) (highest byte)

339) C/I Calculated Power (Interference - Broadband) (lowest byte)

340) C/I Calculated Power (Interference - Broadband) (highest byte)

341) C/I Calculated Power (Interference - Broadband) (lowest byte)

342-400) Not Used

401-2004) Sweep Data

(401 points * 4 bytes/point = 1604 bytes)

4 bytes for each data point

1. dBm

258

(highest byte)

2. dBm

Site Master PM

69

247 Value sent as (value in dB * 1000), valid values are 0 to 20 dB

248 In number of Hz

249 Scaled by Frequency Scale Factor (bytes 318-319)

250 Scaled by Frequency Scale Factor (bytes 318-319)

251 000b = NB FHSS, 001b = Carrier - WB FHSS, 010b = Carrier - Broadband, 111b = Interference

252 Value sent as (value in dBm * 1000) + 270,000

253 If Status Byte 9, bits 1-3 equal 111b, then value will be calculated power for the interference trace as a NB FHSS

signal. Otherwise, these bytes represent the calculated carrier power.

254 Value sent as (value in dBm * 1000) + 270,000

255 If Status Byte 9, bits 1-3 equal 111b, then value will be calculated power for the interference trace as a WB FHSS

signal. Otherwise, these bytes should be ignored.

256 Value sent as (value in dBm * 1000) + 270,000

257 If Status Byte 9, bits 1-3 equal 111b, then value will be calculated power for the interference trace as a Broadband

signal. Otherwise, these bytes should be ignored.

258 Value sent as (Value in dBm * 1000 ) + 270,000

Advertising