background image

51

4. Front Panel BLUE” Light and “RED” Light “ON”

ADS-464 “ON” button does respond ...

a. PROBABLE CAUSES;

1a) EMERGENCY STOP (E-STOP) BUTTONS 1, 2, and 3.

b. POSSIBLE SOLUTIONS;

1b) Verify that ALL EMERGENCY STOP (E-Stop) buttons are pushed in.

EMERGENCY STOP 1 - main enclosed door

EMERGENCY STOP 2 - pendent control

EMERGENCY STOP 3 - rear control panel (2-door models only)

• If ALL EMERGENCY STOP (E-Stop) buttons are “disengaged,” press “ON” located on the

main enclosure door.

• If “NO,” go to section 3 on page 47

Does the system “GREEN” “ON” light illuminate?

• If not, check the EMERGENCY STOP (E-Stop) and drying system “ON/OFF” circuits.

(Refer to ladder diagram.)

5. Front Panel BLUE” (main panel) light, “RED” (sprinkler power) light, and “GREEN” (control

power) light “ON

The system has one or more of the following symptoms;

• OPERATOR INTERFACE TERMINAL - no display or displays “LINE FAULT” message

• PROGRAMMABLE LOGIC CONTROLLER (PLC) - no indicator lights “ON”

• CONVENIENCE OUTLET - no power

• HI-LIMIT CONTROLLERS (HLS1 and HLS2) - no display

a. PROBABLE CAUSES;

1a) Fuse 7 -- PLC (Programmable Logic Controller) power

Fuse 8 -- 24 volt DC power
Fuse 9 -- convenience outlet
Fuse 10 - hi-limit controller power

2a) Malfunctioning PLC (Programmable Logic Controller).