Nilfisk-ALTO CLE2.0 User Manual

Page 12

Advertising
background image

11

4.2.2 Ratio control

This control sets the change of input level to output level but only for the signals that exceed the threshold. The
scale of the ratio control on the front panel (calibrated in dB) indicates how much input level is required to increase
the output level by 1 dB. If you have a ratio equal to 1:1 you will get the same level of input and output signal: So,
no level change.

If you have a ratio of 2:1 this means that for every 2dB increase of the input level (above threshold) you will get
an increase of output level of 1 dB. ON the same way, a ratio of 10:1 means that for every 10 dB increase of the
input level (above threshold) you will get an increase in output level equal to 1dB, and so on.

You need to be aware that higher ratio settings produce less natural sounds so if you wish a more minute effect
on the dynamic range of a program you should use a Ratio of 4:1 or lower.
With the SKC circuit (Smart Knee Control) you can avoid aggressive compression generated by using high ratios.
How we achieve this? Introducing a "soft knee" curve in the range of up to 10dB above the threshold level. Hard
Knee compression is then used beyond this range.

4.2.3 Attack control

The attack time represents the amount of time that passes before the compressor start to lower the
output level when the signal is above the threshold point.

For very fast transients such as drums, handclaps, etc, a short attack time will be used. These peaks
are consequently carefully regulated by the compressor. Sounds of other nature will get advantages if
longer attack times are used. Anyway, our advice is always to begin the process with longer attack times.
Then you can start gradually to reduce the attack time. IN the CLE 2.0 the attack time can be set in a
range of 1 to 150 milliseconds.

Output

Hard Knee

Threshold

Gain 0 dB

Ratio 2:1

Ratio 4:1

Limiter

:1

SKC Curve

Input

Chart. 5 SKC characteristic of the compressor section

4.2.4 Release Control

This control determines how much time the compressor needs to get back to normal gain when the audio
signal falls below the set threshold.

A too short release time will make the volume to fluctuate and you will experience pumping effect. A too long
release time will give you pumping and breathing effect especially when you have loud passage followed by
a quite passage. The release time on CLE 2.0 can be set from 0.05 to 5 seconds.

4.2.5 Auto switch

This switch turns off the possibility of manually set the attack and release times. An intelligent program recogni-
tion circuit will automatically set the attack and release times. In such way, undesirable effects such as distortion
and pumping will be avoided.

4.2.6 Output control

This Control is indispensable to compensate the loss of level at output level generated by the gain reduction caused
by the compression and limiting processing.

4.2.7 Bypass Switch

This switch simply turns off the correspondent channel. This is useful to compare quickly the processed
and unprocessed signal.

Advertising