Aube Technologies TI032-3W User Manual

Ti032-3w, Installation and user guide, Applications

Advertising
background image

TI032-3W

400-032-001-B 30/11/06 1/2

TI032-3W

Installation and User Guide

Programmable Wall Switch

The TI032-3W switch can be used in a single-pole or 3-way installation
with the following types of lighting:

• Incandescent
• Halogen
• Low-voltage halogen with transformer
• Fluorescent

The TI032-3W switch cannot be used with a load below 40 W or above
500 W.

n

Cut power at the circuit breaker to avoid electric shock.

o

Remove the existing switch. (For a 3-way installation, identify and
label the wire that is connected to the “common” screw.)

p

Install the new switch (refer to the appropriate section below).

q

Apply power at the circuit breaker.

SINGLE-POLE INSTALLATION

Connect wires "2" and "C" of the TI032-3W to the line (120 V) wire.

EXISTING 3-WAY INSTALLATION

Connect wire "C" of the TI032-3W to the "common" wire, identified when
removing the old switch. Connect the other two TI032-3W wires to the
two remaining wires.
At the other 3-way switch, connect the jumper wire between the "com-
mon" screw and the screw where wire "1" of the TI032-3W is connected.

NEW 3-WAY INSTALLATION

The jumper wire is not required in this installation. A single-pole
switch can be used as the other switch in a 3-way installation.

n

Pry the switch door open from the
bottom using a small screwdriver.

o

Ensure the ON/OFF selector is set
to ON.

p

Reset the switch using a paper clip.
0:00 and MO will flash.

If the display is blank:

Ensure the ON/OFF selector is properly engaged in the ON posi-
tion. Push it to the right using a small screwdriver.

If the programmable switch controls a lamp equipped with a
built-in On/Off switch, ensure the lamp switch is set to On.

Ensure the light bulb is not burned out and is tightly screwed in its
socket.

EXISTING 3-WAY INSTALLATION
If either switch does not work properly, rewire the jumper between the
"common" screw and the other screw.

WARNING: Before replacing the light bulb, place the ON/OFF
selector in the OFF position. Failure to do so might damage the
switch.

NOTE: The switch displays the time in 24-hour format by default or
following a reset.

n

To change to 12-hour format (or vice versa), proceed as follows:
a) Press one of the control buttons to ensure the MAN or

AUTO indicator is displayed.

b) Press the MIN and HOUR buttons simultaneously and brief-

tly (0:00 display = 24-hour, 12:00 display = 12-hour ).

o

Set the time using the HOUR and MIN buttons. If you have
selected the 12-hour format, ensure that PM appears on the
screen when an afternoon time is displayed.

p

Set the day by using the DAY button.

q

Press one of the control buttons or close the switch door to
return to normal operation.

n

Applications

1.

o

Installation

2.

NOTE A:
The white wire is not the neutral wire but the wire going to the
load.

Line

Neutral

See NOTE A

120 VAC

Line

Neutral

120 VAC

Red

120 VAC

Jumper

Red

3-wire cable

See NOTE A

p

Power-On

3.

q

Setting the Clock

4.

120 VAC

See NOTE A

Control (4)

Reset

On/Off
selector

400-032-001-B ENG (print at 90%).fm Page 1 Thursday, November 30, 2006 8:52 AM