Installing your dryer, Ducting requirements – Samsung DV456ETHDSU-AA User Manual

Page 10

Advertising
background image

10_

installing your dryer

installing your dryer

DuCTInG REquIREmEnTS

• Use a 4-inch (10.2 cm) diameter rigid aluminum or rigid galvanized steel duct.
• Do not use a smaller duct.
• Ducts larger than 4 inches (10.2 cm) in diameter can cause increased lint accumulation.

Lint accumulation should be cleaned regularly.

• If a flexible metal duct must be used, use the type with a stiff sheet metal wall. Do not use a flexible duct

with a thin foil wall. Serious blockage can result if the flexible metal duct is bent too sharply.

• Never install any type of flexible duct in walls, ceilings, or other concealed spaces.
• Keep the exhaust duct as straight and short as possible.
• Secure joints with duct tape. Do not use screws.
• Plastic flexible duct can kink, sag, be punctured, reduce airflow, extend drying times, and affect dryer

operation.

• Exhaust systems longer than recommended can extend drying times, affect machine operation, and

may collect lint.

• The exhaust duct should end with an exhaust hood with a swing-out damper to prevent back drafts and

the entry of wildlife. Never use an exhaust hood with a magnetic damper.

• The hood should have at least 12 inches (30.5 cm) of clearance between the bottom of the hood and

the ground or other obstruction. The hood opening should point down.

• Never install a screen over the exhaust outlet.
• To avoid lint buildup, do not exhaust the dryer directly into a window well. Do not exhaust under a house

or porch.

• If exhaust ductwork must run through an unheated area, the duct should be insulated and slope slightly

down towards the exhaust hood to reduce condensation and lint buildup.

• Inspect and clean the interior of the exhaust system at least once a year. Unplug the power cord before

cleaning.

• Check frequently to be sure the exhaust hood damper opens and closes freely.
• Check once per month, and clean at least one time per year. Note: If clothes are not getting dry, then

check ducting for obstructions.

• Do not exhaust dryer into any wall, ceiling, crawl space, or concealed space of a building, gas vent, or

any other common duct or chimney. This could create a fire hazard from lint expelled by the dryer.

eleCTRIC ANd GAs dRyeR

Weather hood Type

Recommended

Use only for short-run installation

4” (10.2 cm)

2.5” (6.4 cm)

No. of 90° elbows

Rigid

Metallic Flexible*

Rigid

Metallic Flexible*

0

80 ft. (24.4 m)

41 ft. (12.4 m)

74 ft. (22.6 m)

33 ft. (10.1 m)

1

68 ft. (20.7 m)

37 ft. (11.2 m)

62 ft. (18.9 m)

29 ft. (8.8 m)

2

57 ft. (17.4 m)

33 ft. (10.1 m)

51 ft. (15.5 m)

25 ft. (7.6 m)

3

47 ft. (14.3 m)

29 ft. (8.8 m)

41 ft. (12.5 m)

21 ft. (6.5 m)

* Do not use non-metallic flexible duct.

HUDSON STEAM DRYER_IB_DV456E(G)THDSU_DC68-03170C-03_EN.indd 10

2013-12-16 16:44:26