Installation, A. preparing the rear wall for outside back, Exhaust – Samsung SMH1927S-XAA User Manual

Page 15: B. attach the mounting plate to the wall . 15, Step-by-step installation guide, C. outside back exhaust (horizontal duct), B. attach the mounting plate to the wall

Advertising
background image

14

Step-by-step installation guide

15

Step-by-step installation guide

C. OUTSIDE BACK EXHAUST (HORIzONTAL DUCT)

5. Rotate the blower unit counterclockwise 180 °.

6. Place the blower unit back into the opening.

CAUTION: Do not pull or stretch the blower

unit wiring. make sure the wires are not

pinched.

NOTE: The blower unit exhaust openings

should match exhaust openings on the rear of

microwave oven.

7. Close the Blower Plate and attach the exhaust

adaptor to the rear of the oven by sliding it into

the guides at the back top center of the oven.

Push in securely until it is in the lower locking

tabs. Take care to ensure that the damper hinge

is installed so that it is at the top and that the

damper swings freely.

B. ATTACH THE mOUNTING

PLATE TO THE WALL

Attach the plate to the wall using toggle bolts. At

least one wood screw must be used to attach the

plate to a wall stud.

1. Remove the toggle wings from the bolts.
2. Insert the bolts into the mounting plate through

the holes designated to go into drywall, and

then reattach the toggle wings so that ¾˝ of the

bolt protrudes beyond the wing.

INSTALLATION OVERVIEW

A. Prepare Rear Wall (horizontal duct only)
B. Attach Mounting Plate to Wall
C. Prepare Top Cabinet
D. Mount the Microwave Oven
E. Connecting Ductwork (vertical duct only)

A. PREPARING THE REAR

WALL FOR OUTSIDE BACK

EXHAUST

You need to cut an opening in the rear wall for

outside exhaust.

CL

• Read the instructions for outside back exhaust

on the REAR WALL TEMPLATE.

• Tape the REAR WALL TEMPLATE to the rear

wall.

• Cut the opening, following the instructions on

the REAR WALL TEMPLATE.

CAUTION: Do not cut an opening in the rear wall if

you are installing the microwave with vertical duct or

non-vented ductless ventilation.

3. INSTALLATION

SMH1927_XAA_DE68-04108A-01_EN_120725.indd 15

2012-07-25 �� 7:54:35

Advertising
This manual is related to the following products: