SECTION 5 - MAINTENANCE


The following maintenance schedule is recommended:

Action

Description

Frequency

Visual inspection

Inspect the antenna, cables and
connections. Ensure that the cable is
attached properly and the unit has not been
damaged.

Every 6 months

Performance
test

Verify that the system is operating by
using the training mode with a training
beacon

Every year

Clean exterior

Using a mild, sudsy solution such as
dishwashing liquid, wipe the surface of
the ARX-50 with a damp cloth to
remove film, salt and sand

As needed

APPENDIX A - SPECIFICATIONS


General
Carrier frequency

121.5 MHz or 121.65 MHz, user selectable

Sensitivity

<0.2 µV (at antenna output)

VHF antenna

Flexible monopole

Modulation

Swept tone

Electrical input power

+10.5 V to +28 V DC, 120 mA average, 400 mA
maximum

Alert methods

Bright red flashing led

L

oud audible alarm (≈70dBA @ 1m)

External speaker connection (8v maximum)

Relay contacts: normally open (2 A/30 V
maximum)

Regulation conformity
Safety

IEC 60945, EN50371

EMI/EMC

IEC 60945

RoHS/WEEE

European Directive 2002/95/EC

Physical
Dimensions

5.3” X 3.7” X 1.5” (13.46 X 9.40 X 3.81cm)

Weather resistance

IP65 (when included monopole antenna is
correctly installed)

Operating temperature

-4

°F to +131°F(-20°C to +55°C)

Storage temperature

-40

°F to +158°F (-40°C TO +70°C)

Weight

0.8 lbs (362.87 g)

Advertising