Residential hybrid electric heat pumps, Distributed by – American Water Heater HPE6280H045DV User Manual

Page 2

Advertising
background image

Order Entry and Sales
500 Princeton Road (FEDEX, UPS)
Johnson City, TN 37601-2030
P.O. Box 4808 (Mailing)
Johnson City, TN 37602-4808
(800) 937-1037
FAX (800) 581-7224

No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system, without permission in writing from American Water Heaters.

Distributed By:

Warranty and Service

500 Princeton Road (FEDEX, UPS)

Johnson City, TN 37601-2030

P.O. Box 1597 (Mailing)

Johnson City, TN 37605-1597

(800) 456-9805

FAX (800) 999-5210

Residential Hybrid Electric

Heat Pumps

NRXSS00109 Revised August 2010

All dimensions in inches.
*Increased storage capacity provides the same 2.3 Energy Factor both in EFFICIENCY and HYBRID modes.

MODEL

GAL

CAP.

ENERGY FACTOR

BY MODE*

1ST HOUR RATING/GAL

BY MODE

HEIGHT

DIAMETER

SHIPPING

WEIGHT (LBS)

HPE10280H045DV

80

2.3

2.3

.85

70

84

76

81.5

24.5

410

ELECTRONIC USER INTERFACE
– Large LCD touch pad display
– Intuitive icons clearly indicate the current

operation mode

Individual backlit buttons for mode selection:


Hybrid

Electric

Vacation

Three-line display communicates current status
and displays error messages in plain English
when applicable

Safety lock

EFFICIENCY MODE
– Utilizes the heat pump for all water heating
– Automatically reverts to heating element if ambient air or water

temperatures are outside optimal operating range for heat pump

HYBRID MODE
– Utilizes the heat pump or heating element, depending

on demand

E

VACATION MODE

LECTRIC MODE

Standard electric water heater operation

One touch operation maintains tank temperature of 60° F (15.6° C)
during vacation or extended absence to reduce operating costs and
provide freeze protection

Other Features:
• Powered anode to protect against tank

corrosion (Max 50 mA draw)

• 2 Inch “Environmentally-Friendly” non-CFC foam

insulation reduces standby heat loss


• Child resistant brass drain valve

CSA certified and ASME rated T&P relief valve

Water temperature set point range; 95

º

F to

150

º

F (35

º

C to 66

º

C)

Operating Requirements:

Requires provision for condensate draining; if
a suitable drain is not available a condensate
pump is required

Recommended minimum 750 cubic feet of
space for air circulation heat exchange
240 VAC single phase power supply with 25
amp circuit breaker

E

D

C

A

B

MODEL

GALLONCAPACITY

ENERGYFACTORBYMODE

1STHOURRATINGBYMODE

HEIGHT

(Inches)

DIAMETER

(Inches)

HEIGHTTOWATER

OUTLET(Inches)

HEIGHTTO

DRAINVALVE

(Inches)

HEIGHT



TO T&P
(Inches)

Approximate

Shipping

Weight(LBS)

EFFICIENCY*

HYBRID ELECTRIC EFFICIENCY HYBRID ELECTRIC

A

B

C

D

E

HPE10260H045DV

60

2.40

2.33

0.88

51

68

66

67Ͳ1/3

24Ͳ1/2

41

4Ͳ1/4

40

332

HPE10280H045DV

80

2.30

2.33

0.85

70

84

76

81Ͳ1/2

24Ͳ1/2

55

4Ͳ1/4

56Ͳ1/3

410

*Up to a 2.4 Energy Factor (EF) ra ng in Effi

ciency Mode.

HEIGHT TO

WATER INLET

(Inches)

227428 NRXSS00109 2