Etting, Tarted, Preparation for installation – Samsung AW05NCM8XAA User Manual

Page 14

Advertising
background image

E-

4

 Always have an assistant to help you. Never attempt to install

any air conditioner alone.

 You risk the possibility of hurting yourself or injuring others by

attempting to install it alone.

Preparation for Installation

1 Carefully remove the unit from the packing case, lay it on

the floor and check that all accessories (as indicated on page 16) are enclosed.

2 Check the cabinet and front grille of the unit for any defects such as

scratches.

3 Be sure to check the power supply.



Refer to the specifications on the label attached to the unit.

Checkpoints Prior to Installation

Installation Conditions

1

Electrical Requirements

For personal safety:

This appliance must be properly grounded.

Do not, under any circumstances,cut or remove the third

grounding prong from the power cord.

We recommend that you do not use an extension cord or an

adapter plug with this appliance.

Do not change the plug on the power cord of this appliance.

Follow national electrical codes or local codes and ordinances.

115V

15 AMP circuit

"parallel" type

230-208V

20 AMP circuit

"perpendicular" type

230-208V

15 AMP circuit

"tandem" type

230-208V

30 AMP circuit

"tandem" type

If the electric supply provided does not meet the above

specifications, call a licensed electrician.

Aluminum house wiring may pose special problems consult

a qualified electrician.

This unit requires a separate circuit, serving only this appliance.