Chapter 5: CPS Appliance Commands 49

Example

The following command sets a baud rate of 57600 and enables XON/XOFF flow control on port 2.

> port 2 set baud=57600 flow=xonxof

Port Set In/Out command

The Port Set In/Out command specifies how carriage returns (CR) and linefeeds (LF) are treated in
incoming or outgoing serial data on one or all ports.
Access right: SCON or PCON
Access level: ADMIN or APPLIANCEADMIN

SOCKET=<socket>

TCP port that must be entered on the Telnet client to connect to this serial port. The
new value becomes effective in subsequent sessions.
When SSH is enabled, the CPS appliance automatically adds 100 to the specified
value. When All is specified, port 1 will be assigned the specified socket value plus 1,
port 2 will be assigned the specified value plus 2, and so on. When All is specified
and SSH is enabled, port 1 will be assigned the specified socket value plus 101, port
2 will be assigned the specified value plus 102, and so on.
Default = 3000 plus the port number, 3100 plus the port number if SSH is enabled;
see above for action taken if All is specified

CHAR=^<cli_char>

CLI access character in the range A to _ (underscore) or None. (The allowable ASCII
range is 0x41-0x5F and 0x61-0x7A.) The CLI access character, when pressed
simultaneously with the Ctrl key during a session with an attached serial device, will
suspend the session with the device and place you in CLI command mode. If None is
specified, the value specified in the Char parameter of the Server CLI command will
be used.
Default = None

TOGGLE=NONE|DTR

When set to DTR, the CPS appliance will toggle the port’s DTR-out signal off for 1/2
second each time a connection is made to the port. This toggle is required to awaken
the console port of some devices.
Default=None

POWER=<signal>

Control signal to monitor and the state that indicates the target device has power on.
The entire value must be specified; abbreviations are not allowed. The power status
monitoring signal cannot also be used for flow control. Valid values are:
None

Disables power status monitoring.

HICTS

CTS high indicates power on.

LOCTS

CTS low indicates power on.

HIDCD

DCD high indicates power on.

LODCD

DCD low indicates power on.

HIDSR

DSR high indicates power on.

LODSR

DSR low indicates power on.

Default = None

Table 5.8: Port Set Command Parameters (Continued)

Parameter

Description