Installation

2

Smart-UPS RT SURTA1500XL/SURTA1500XLJ/SURTA2000XL Uninterruptible Power Supply User Manual

– Do not operate the UPS where there is excessive dust or the temperature or humidity are

outside the specified limits.

Installation

Refer to instructions below for information on how to install the UPS in a rack, as a tower configura-
tion, or when installing the UPS with optional battery pack(s). Once the UPS has been placed in the
desired tower or rack location, complete the remaining installation steps in sequential order, beginning
with “Connect Equipment to the UPS” on page 2.

To Install the UPS in a Rack

See the installation sheet supplied with the optional rail kit (SURTRK) to install the UPS in the rack. It
is recommended that you remove the battery before attempting to install it in the rack. See “Battery
Replacement Instructions” on page 11
for the procedure.

To Install the UPS as a Tower Configuration

To Install the UPS with External Battery Pack(s)

In addition to the UPS, if your configuration includes optional Smart-UPS RT battery pack(s)
(SURTA48XLBP or SURTA48XLBPJ), see the battery pack user manual to complete the physical
installation for the UPS with external battery pack(s).
The UPS must be installed above external battery pack(s) when in a rack. When installing the UPS as
a tower configuration, battery pack(s) must be installed to the right of the UPS when facing the front
of the UPS. Failure to follow these instructions could result in cabling shortage.

Connect Equipment to the UPS

The UPS is equipped with the following connectors.

Caution

For stability, the UPS is shipped with stabilizing feet. Removal of the feet in a

tower configuration may result in bodily injury or equipment damage.

Caution

Prior to connecting the grounding cable, ensure that the UPS is NOT connected to

utility or battery power circuits. See step 3 on page 3 for procedure.

Connectors

Type

Description

Serial Com

Use only the supplied cable to connect to the serial port.
N

OTE

: A standard serial interface cable is incompatible with the UPS.

USB Com

100 V Models: Users may purchase software and cables as an accessory
to the UPS. Refer to the APC web site,

www.apc.com

for information

on accessories.

N

OTE

: Serial and USB ports cannot be used simultaneously.

2.5

cm

2.5

cm

40°C

104°F

0%

95%