Take a closer look, Two mounting base options – American Dynamics Tyco VII User Manual

Page 3

Advertising
background image

take a closer look

1

This distance is for the AD-UTC data only. See cable manufacturers specifications for video
capabilities.

On-screen text supports six languages: English, French,
Italian, Spanish, German and Portuguese.

Password protection prevents unauthorized use of the
configuration utility.

The dome incorporates an innovative twist lock release
from the mounting base for easy installation and servicing.

The fully isolated power supply helps eliminate ground
loops.

Users can set line-lock on or off. Line-lock is enabled to
help prevent vertical rolling in multi-camera applications.

Vertical sync phase adjustment is provided to help
compensate for different phases of power when
line-lock is enabled, making it ideal for single and
multi-phase power installations.

Sensing of 50/60 Hz lines is automatic and does not
require manual adjustment.

Surge protection is provided for video, code, alarms
and power connections.

Daisy chain configuration of control wiring is enabled:

- For RS-422: 10 domes at a maximum distance of 1

km (3000 ft) on two 22 AWG shielded twisted pairs
(STP)

- For SensorNet: 32 devices at a maximum distance

of 1 km (3000 ft) on one 22 AWG unshielded twisted
pair (UTP)

- For Manchester: 3 domes at a maximum distance of

1500 m (5000 ft) on one 18 AWG shielded
twisted pair (STP)

- For AD-UTC

1

: Maximum distance per dome is 700 m

(2300 ft) on 20 AWG RG59U cable

The features of the SpeedDome Ultra VII with EIS
can be extended to outdoor environments via the
SpeedDome Ultra Outdoor Housing. The outdoor
housing, designed especially for the SpeedDome Ultra’s
small, unobtrusive size, makes it the perfect
protection for the dome. The housing now features a
reinforced outdoor housing as standard and a heavy
duty vandal resistant housing kit option.

Two Mounting Base Options

The housing/eyeball assembly twist locks into both

mounting bases. The I/O board base connects the

housing/eyeball assembly in one step. Power, communication

and video cables (or composite cable) are connected one

time to an I/O PC board in the mounting base, so the

assembly is simply twist locked onto the base. Service

and maintenance are easy and can be accomplished

without a ladder or lift via the installation/removal tool. The

I/O board mounting base supports four alarm inputs and

four alarm outputs as well as power and communication

LEDs. The standard base connects the housing/eyeball

assembly in two steps. First, power, communication and

video cables (or composite cable) are inserted through the

base and attached to the assembly. Then the assembly

is connected to the base. The standard mounting base

supports one alarm input and one alarm output. The

installation/removal tool cannot be used to install this

configuration.

with I/O Board
Mounting Base

with Flying Lead

Mounting Base

(Pigtail)

N U M B E R O F P R E S ET S

C o n t r o l l e r o r
M a t r i x S w i t c h e r

P r o t o c o l

N u m b e r o f P r e s e t s

ADTT16E

SensorNet

96

RS-422

2

4

MegaPower LT

AD-UTC

96

SensorNet

96

AD2150

Manchester

64

RS-422

3

16

MegaPower 48 and

SensorNet

96

MegaPower 48 Plus

Manchester

64

RS-422

96

VM96

SensorNet

Unlimited

RS-422

Unlimited

MegaPower 168

SensorNet

64

Manchester

64

RS-422

64

RS-422

3

16

MegaPower 1024

Manchester

4

64

RS-422

3

16

Third party interfaces

RS-485

96

2

Using SensorNet-to-RS-422 Converter (model number RCSN422)

3

Using RS-422 Code Distributor (model number AD2083-02B)

4

Using Manchester Code Distributor (model number AD2091)

Advertising