Troubleshooting, Cu 700 – AKG Acoustics CU700 User Manual

Page 10

Advertising
background image

8

Troubleshooting

10

CU

700

Problem

Possible Cause

Remedy

All LEDs dark.

No defect. STATUS LEDs are not acti-
vated before you insert a transmitter
with batteries into a charging slot.

All LEDs dark although at least one charg-
ing slot is loaded.

1. AC adapter is not connected to power.

2. DC cable is no not connected to

charger.

3. One or more charging contacts fail to

make contact with the transmitter.

4. Internal error.

1. Connect power supply to convenient

power outlet.

2. Connect DC cable to charger.

3. Check contacts for resilience, or clean

contacts.

4. Disconnect power supply or DC cable,

wait for 10 seconds, and connect
again.
Should the problem persist, contact
your nearest AKG Service Center.

STATUS LED flashing red.

Charging cycle has been stopped:

1. Transmitter uses dry batteries.

2. Charging contacts contaminated.

3. Inside temperature of batteries is too

high.

4. Inside temperature of charger is too

high.

5. Batteries defective (voltage <0.5 V).
6. Charger connected to incompatible

power supply whose output voltage is
too high: both STATUS LEDs flashing
red.

7. Charger defective.

1. Remove transmitter from charging

slot; replace dry with rechargeable
batteries.

2. Clean charging contacts on charger

and transmitter with soft cloth.

3. Allow batteries/charger to cool down,

charging cycle will resume when tem-
perature returns to acceptable range.
Should the problem persist, contact
your nearest AKG Service Center.

4. Make sure there is enough free space

around charger to provide adequate
heat dissipation.

5. Replace batteries.
6. Use original AC adapter supplied with

charger.

7. Contact your nearest AKG Service

Center.

CU 700_D030915_Quad_Manual 08/18/2009 14:46 Seite 10 (Schwarz/Black Auszug)