SYSTEM PROGRAMMING - Menu 1

PAGE 4

INSTALL MANUAL

QUICK VIEW WIRE DIAGRAM

1
2
3

1
2
3

1
2
3
4

Position 1 or Position 2

GREEN

BLUE

N/A*

RED

BLACK

WHT/VIOLET

SELECTABLE PARK LIGHT OUTPUT

OUTPUT TO ACTIVATE DOOR LOCK CIRCUIT (-)

OUTPUT TO ACTIVATE DOOR UNLOCK CIRCUIT (-)

OUTPUT FOR VOLTAGE INVERTER*

12VOLT OUTPUT FOR BYPASS MODULE

GROUND OUTPUT FOR BYPASS MODULE

(-) WHILE RUNNING OUTPUT (BYPASS TURN ON) / STARTER DISABLE

* THE CENTER PIN OF THE KEYLESS CONNECTOR IS LOW CURRENT AND IS DESIGNED
TO SUPPLY POWER TO DOOR LOCK MODULES (DO NOT CONNECT TO RELAYS)
OVERLOADING THIS OUTPUT WILL DAMAGE THE MODULE!
**THIS CONNECTOR IS USED FOR ALARM MODELS ONLY.
*** FOR USE WITH COMPATIBLE BYPASS MODULES ONLY.

BY DEFAULT THE SYSTEM COMES WITH THE PARK
LIGHT JUMPER SET FOR POSITIVE PARK LIGHT
OUTPUT. TO CHANGE THE SYSTEM TO A NEGATIVE
PARK LIGHT OUTPUT, PLACE THE JUMPER IN THE
NEGATIVE PARK LIGHT POSITION SHOWN IN THE
DIAGRAM. (Position 2)

POSITIVE
PARK LIGHT

NEGATIVE
PARK LIGHT

72 SERIES

SYSTEM PROGRAMMING - Menu 1

PAGE 5

INSTALL MANUAL

QUICK VIEW PROGRAMMING

Press Lock

Press Unlock

Press Start

Press #

MENU 1

MENU 2

MENU 3

MENU 4

1 - Cycle the Ignition Key On/Off On/Off On (Leaving the key ON)
2 - Press and release the Program Switch located on the antenna 1 time.
*The Horn will chirp and the park light will turn on to confirm that the system
has entered Program Mode.
3 - Select the Program Menu by pressing the button that corresponds to the
desired Program Menu.

ENTERING PROGRAM MODE

1 - Cycle the Ignition Key On/Off On/Off On (Leaving the key ON)
2 - Press and RELEASE the Program Switch 1 time.
(Horn will chip to confirm program mode has been entered)
3 - Press and HOLD the Program Switch for 5 seconds or until the Horn Chirps 3
times.
4 - Turn the ignition key OFF to exit.

4 - Press and Release the Program Switch to advance through the settings.
*The horn will chirp and LEDs flash the same number of times as the selected setting.
5 - Press and hold the Program Switch to change the setting.
(The horn will honk and the park lights will flash to indicate the option selected)
6 -
To exit Program Mode, turn the key off.
(Confirmed by Long Horn Chirp)

72 SERIES

SYSTEM RESET

BYPASS MODULE DATA COMMUNICATION PORT***

*The default setting is for idatalink modules. For Fortin bypass modules power-
up the system with the Fortin module connected to the data port to set the default
to Fortin bypass module.

Note- The 1172 can only control features related to the Unlock and Start buttons.