54

General features

Efficiency:

65% typical when measured at nominal input and rated load.

Input protection:

Protection against wrong polarity if the +24 V input voltage is mistakenly
reversed.

Output protection:

If for some reason the power supply fails to control itself, the built-in
over-voltage protection circuit will shut down the outputs to prevent dam-
age to external circuits. The trip point of the

crowbar circuit is approximately 5.7 ~ 7.0 V. The power supply will go
into hiccup mode under short circuit or overload

conditions, and will recover automatically when such conditions cease to
exist.

Environmental specifications

Operating temperature: 0 ~ 45° C

Storage temperature:

-40 ~ 75° C

International standards compliance

Safety:

UL 1950 D3

CSA 234

TUV EN 60950