Fuel demand valve, Atory-compliant ted fuel systems. ystems, Outlet to engine inlet from tank – Attwood 8M004689 User Manual

Page 2

Advertising
background image

FUEL DEMAND VALVE

©2010 Attwood Corporation

Lowell, MI 49331

www.attwoodmarine.com

A-FUELDV-10

Attwood’s Fuel Demand Valve (FDV) provides a unique
solution

for managing pressurized fuel lines and fuel tanks that are required due to EPA regulatory

requirements for portable fuel system evaporative emission controls. The Fuel Demand Valve eliminates

pressurized fuel from reaching downstream fuel lines and your engine, ensuring that fuel is

provided to the engine on demand rather than as a result of pressure in the tank.

Installs in-line between your fuel tank and primer

bulb/fuel pump

Eliminates fuel fi tting spray when connecting and

disconnecting fi ttings at the engine

Eliminates fuel spill due to pressurized fuel tanks and fuel lines

Pad printable: Customizable with your company logo

Eliminates potential service and warranty issues related to

pressurized fuel lines

Available individually or as part of a fuel line assembly

Count On Attwood as Your Partner for Safe, Regulatory-Compliant
(EPA & CARB), Cost Effective Portable and Integrated Fuel Systems.

CFR 40 1060.105 (c)

Effective January 1, 2010 – Portable marine fuel tanks and associated fuel-system components must meet the following requirements:

1 They must be self-sealing (without any manual vents) when not attached to the engines. The tanks may not vent to the atmosphere

when attached to an engine.

2 They must remain sealed up to a positive pressure of 24.5 kPa (3.5 psig); however, they may contain air inlets that open when there is a

vacuum pressure inside the tank. Such fuel tanks may not contain air outlets that vent to the atmosphere at pressures below 34.5 kPa (5.0 psig).

e tank.

atory-Compliant

ted Fuel Systems.

ystems.

Patent

Pending

OUTLET

TO ENGINE

INLET
FROM TANK

Attwood Part Number

8M0044687

8M0044688

8M0044689

Operating Temperature

-20˚C to 80˚C (-4˚F to 176˚F)

-20˚C to 80˚C (-4˚F to 176˚F)

-20˚C to 80˚C (-4˚F to 176˚F)

Storage Temperature

-40˚C to 80˚C (-40˚F to 176˚F)

-40˚C to 80˚C (-40˚F to 176˚F)

-40˚C to 80˚C (-40˚F to 176˚F)

Operating Input Pressure

138 kPa (20 psi) protected for

138 kPa (20 psi) protected for

138 kPa (20 psi) protected for

276 kPa (40 psi) psi pressure spike

276 kPa (40 psi) psi pressure spike

276 kPa (40 psi) psi pressure spike

Minimum Engine Vacuum

-1 kPa (-6" gasoline)

-4 kPa (-21" gasoline)

-7 kPa (-35" gasoline)

Flow Performance

125 L/H (33 GPH) at <2 kPa (10" gasoline)

125 L/H (33 GPH) at <2 kPa (10" gasoline)

125 L/H (33 GPH) at <2 kPa (10" gasoline)

Hose Size

8 mm - 10 mm (5/16" - 3/8")

8 mm - 10 mm (5/16" - 3/8")

8 mm - 10 mm (5/16" - 3/8")

Siphon Protection

None

0 mm - 381 mm (15")

381 mm - 762 mm (30")

Manual Override

Yes

Yes

Yes

Application

Above Deck

Above Deck

Above Deck

Text Color

White

Red

Yellow

Advertising
This manual is related to the following products: