TROUBLE SHOOTING

This is a self-diagnostic control system. The system will
automatically display flashing indicators if a problem is
detected.

No display at topside

No display at topside

- check that the topside is correctly plugged into spa

pack

- the power is on
- if problem persists contact Smart Protect Warranty

Display is flashing

Display is flashing

A power failure must have occurred and the spa pack
has returned to its default values. Press any key to stop
the flashing and then reprogram the filter cycle.

Pump has started up for 1 minute on several occasions

Pump has started up for 1 minute on several occasions

and “Filter” indicator is flashing

and “Filter” indicator is flashing
This is a feature of the SMART WINTER MODE.
It protects your spa from the cold by turning the pump
on for 1 minute several times a day to prevent water
from freezing in the pipes.

W

W

ater temperatur

ater temperatur

e is flashing

e is flashing

This indicates that the spa water temperature is over
112° F(44°C).
DO NOT

enter the water! Remove spa cover and allow

the water to cool down. The system will reset itself
when the water temperature reaches 109°F(43°C)
Call Smart Protect Warranty if the problem persists.

Gr

Gr

ound Fault Interr

ound Fault Interr

upter T

upter T

rips

rips

- Be sure that the neutral on the GFCI has been wired

properly in the main panel.

- Check if it does it only when heat turns on, if so check

element by removing the power to the element termi-
nal and turn the heat on. If it only faults when the ele-
ment is connected with power, the element has a
ground fault and must be replaced.

- This can be done by unplugging the pump, ozonator,

or any other peripheral equipment as a process of elim-
ination to see where the fault may be.