Safety Precautions

Read all safety precautions and installation instructions carefully

before installing or servicing this fixture. Failure to comply with

these instructions could result in potentially fatal electric shock

and/or property damage.

It is recommended that a qualified electrician perform all wiring. This

fixture must be wired in accordance with all national and local

electrical codes.

Do not handle any energized fixture or attempt to energize any

fixture with wet hands or while standing on a wet or damp surface or

in water.

This fixture is designed for use in a 120-277VAC, 60Hz.

Do not use on a dimming circuit.

To reduce the risk of electrical shock, and to assure proper operation,

this fixture must be adequately grounded. To accomplish proper

grounding, there must be a separate ground wire (green) or bare metal

contact (metal conduit) between this fixture and the ground

connection of your main power supply panel.

This fixture is intended to be used for general indoor lighting in dry

or damp locations only.

Assembly Instructions

1.

Preparing for installation

A. Disconnect electrical power before installing or servicing any part of this fixture.

B. Remove fixture; place the diffuser (6) and the bag with hardware off to the side.

2.

Wiring.

All wiring must take place inside junction box.

Caution: Make sure power is off at fuse or circuit breaker box. Check power wires for damage or

scrapes. If power supply wires are within three inches of ballast use wire suitable for at least 90C

(194F). Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult a qualified

electrician before installing.

A. This unit will not operate properly unless connected to a “grounded” electrical circuit.

Electrical shock, over heating, low or no light output, and shortened lamp life can result if

proper grounding is not done. Securely attach green (or green and yellow) wire to back of

fixture with provided hardware.

B.

3.

Fixture mounting.

A. Back pan mounting options Caution: fixture must be mounted at least 18” from ceiling

1. Gem Bar Mounting – Secure gem bar (4) (provided) to junction box (not supplied) with

#8-32 x 1” screws (provided). Install 2” stem (5)(provided) into the gem bar. Use the

lock nut to secure stem at the proper length. Install Back pan (2) over stem and secured

in place with knob (3). (Note: Adjust length of stem to create secure fit.)

2. Secure to junction box – Holes supplied in back pan (2) enable direct mounting to

junction box (not supplied).

3. Secure to Wall – Holes supplied in back pan (2) enable direct wall mounting (hardware not supplied).

4. Install appropriate lamps (1) (not supplied) by inserting lamp pins into lamp holder and press until lamp snaps in place.

4. Diffuser installation

A.

To install the diffuser (6), align diffuser above frame (2), Slide diffuser under trim bands.

B.

Restore power at fuse or circuit breaker box.

Limited Factory Warranty

American Fluorescent Corporation hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating

conditions for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components;

it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.

Using luminaire disconnect (provided), insert white supply wire into the hole across from

white ballast lead. Insert black hot supply wire into hole across from black ballast lead. Do

not mix wires. Pull on each wire to make sure connections are secure. Make certain no

bare wires are exposed outside of luminaire disconnect.