1 of 1

Limited Factory Warranty
American Fluorescent Corporation warrants this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions for a
period of 3 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components; it does not cover failure
due to improper installation, misuse, mishandling or damage incurred in transit

Safety Precautions

Read all safety precautions and installation instructions carefully before
installing or servicing this fixture. Failure to comply with these
instructions could result in potentially fatal electric shock and/or
property damage.

It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.

Do not handle any energized fixture or attempt to energize any fixture
with wet hands or while standing on a wet or damp surface or in water.


This fixture is designed for use in a 110-120VAC, 60Hz fused circuit.
Do not use on a dimming circuit.

To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) contact
between this fixture and the ground connection of your main power
supply panel.

This fixture is intended to be used for general indoor lighting in dry or
damp locations only.

ASSEMBLY INSTRUCTIONS

1. Preparing for installation

A. Disconnect electrical power at fuse or circuit breaker box before installing or servicing any part of this fixture.
B. Carefully remove the fixture from the carton, and check that all parts are included, as shown in figure below. Be careful not to misplace any
of the screws or parts which are needed for installing the fixture.

2. Wiring-all wiring must take place inside
junction box.

Caution: Make sure power is off at fuse or circuit breaker
box. Check power wires for damage or scrapes. If power
supply wires are within three inches of the ballast power
supply, use wire suitable for at least 90C (194F). Note:
Most dwellings built before 1985 have supply wire rated to
60C. Consult a qualified electrician before installing.

A. Secure gem bar (1) on the junction box (not supplied)
with two screws (2) (supplied). Adjust the effective length
of the fixture mounting screws as necessary.
B. Make all wire connections to appropriate wire. Secure
with wire nuts (supplied).

C. The black wire from the fixture is connected to the black
wire from power source.

D. The white wire from the fixture is connected to the white
(neutral) wire from power source.

E. Tuck all connections neatly into junction box.

3. Mounting

A. Thread screws (3) on gem bar (1).
B. Install back panel (4) over screws (3) and secure it with
the two thumbnuts (5) (supplied).
C. Install 18W GU24 lamp (6) (supplied) per label. Insert
lamp into lamp holder (7) and turn it counter clock wise
until lamp snaps in place.
4. Shade-To install the shade (8) slide it into the two shade
guides (9).
5. Restore power at fuse or circuit breaker box.