NLL SERIES

Line Voltage LED Undercabinet Fixture

Models 8, 14, 22, 32 & 40

Plug-in or Hard Wire, Linkable

Page 1 of 2

8060733 R3

Safety Precautions

Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.

It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.

Do not handle an energized fixture or attempt to energize any fixture
with wet hands or while standing on a wet or damp surface or in
water.

Make sure that the power source conforms to the requirements of the
fixture. (See labels on fixture housing).
To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded.


LED lamp and heat-sink are HOT when energized!
Do not touch LED light engine or heat-sink.

12-inch minimum spacing distance from luminaire
required for all objects located under fixture.

This fixture is to be used for general indoor lighting in dry locations
only. Linkable total wattage is 200 Watts

This fixture is dimmable in the high (II) setting only. The following
dimmers are approved for use to achieve smooth dimming down to
10% of full scale:

Leviton – 6633, 6681, 6621-WWP, 6631-WWP
Lutron – TG-600P, TG-603P
Legrand / Pass & Seymour – T600WV, WS700TCCCVG
Cooper – 6013W

Assembly Instructions

1. Preparation for Installation

A. Disconnect electrical power before installing or servicing

any part of this fixture.

B. Place fixture on a clean flat surface with lens (1) towards

you.

C. Open glass lens (1) by lifting both hinge tabs (2) at each
end.
D. LED Light Engine (3) is fixed, DO NOT remove or adjust.
E. Determine input power method (Cord, Hardwire or Link)

and follow corresponding directions below.

2.

Cord to Outlet Installation

(Skip this step if using Hardwire or Link-to-Fixture
Installation)

A. Fixture must be mounted within 5’ of an outlet. Locate the

5’ power cord included in the box.

B. Connect Cord to fixture by snapping the quick connect end of the cord to the corresponding connector in the end of the fixture marked

“IN”. The cord will only connect to the “IN” connector so make the right connector is identified. Do not force the connection, it should
snap in easily.

C. Follow the directions for Mounting and Lamping below.
D. Once Mounting and Lamping are completed, plug the cord into the outlet.

3.

Hardwire Installation Preparation

(Skip this step if using Cord to Outlet or Link-to-Fixture Installation to Power Unit)

A. Discard Cord if Hardwire Installation is

used.

B. Disengage cover (4) by rotating two retaining

tabs (5). Rotate cover 90º.

C. Remove appropriate 1/2” diameter knockout

for supply wiring entry.

D. Determine appropriate connector:

i) Cable connector (7) is included.
ii) Flexible conduit BX (AC) 3/8”trade size

cable (8) (not included).

iii) Anti-short bushing (not included).

E. Insert cable connector (7) into the housing

open hole. Secure it with the nut.

F.

Determined the length of BX cable (8) and add
about 8” (tbd) for the stripping purposes. Cut
the required length of the cable. Trim away the insulation. Push the exposed wires (hot, neutral and ground) through the anti-short bushing
and slide this bushing all the way down to the exposed wires until it is snug up against the armor.

G. Follow the directions below for Mounting, and then proceed to Hardwire Installation Completion.