Gas specifications for non-ce approved dryers, Gas specifications for ce approved dryers – American Dryer Corp. MLG33 User Manual
Page 14
14
Maytag Co.
113413 - 11
Gas Specifications for Non-CE Approved Dryers
***
Gas Type and
Nominal Heating Value
Supply
Pressure
**
Gross
Heat Input
Orifice Size
**
Orifice
(Injector)
Quantity
Burner
Pressure
B tu /ft
3
in WC
Btu/hr
kW
DMS
mm
in WC
Natural
1,000
7.0-13.0
55,000
16.12
20
4.089
1
3.0
*
Liquid Propane
2,500
11.0
55,000
16.12
44
2.184
1
10.0
Heat Input/Gas Consumption/Orifice (Injector) Data (For Non-CE [European] Models Only)
Shaded areas are stated in metric equivalents
*
Gas valve’s internal regulator disabled.
** Information is per pocket/tumbler.
*** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Shaded areas are stated in metric equivalents
*
Gas valve’s internal regulator disabled.
** Information is per pocket/tumbler.
*** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)
NOTES _____________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
Gas Specifications for CE Approved Dryers
***
Gas Type and
Nominal Heating Value
Supply
Pressure
**
Gross
Heat Input
**
Fuel
Consumption
Orifice Size
**
Orifice
(Injector)
Quantity
Burner
Pressure
B tu /ft
3
mb
Btu/hr
kW
DMS
mm
mb
Natural (I
2H
/I
2E
)
1,000
15-30
55,000
16.12
1.557 M
3
/H
22
3.988
1
6.9
Natural (I
2L
)
830
20-35
55,000
16.12
1.876 M
3
/H
22
3.988
1
9.5
Natural (I
2 E L L
)
830
15-30
55,000
16.12
1.876 M
3
/H
22
3.988
1
9.5
*
Natural (I
2E+
)
1,000
20
55,000
16.12
1.557 M
3
/H
31
3.048
1
—
830
25
55,000
16.12
1.876 M
3
/H
31
3.048
1
—
*
Butane (I
3+
)
3,175
28-30
55,000
16.12
1.162 kg/H
48
1.930
1
—
*
Propane (I
3+
)
2,500
37
55,000
16.12
1.162 kg/H
48
1.930
1
—
Butane (I
3B/P
)
3,175
28-30/50
55,000
16.12
1.162 kg/H
44
2.184
1
18.1
Propane (I
3P
)
2,500
28-30/50
55,000
16.12
1.162 kg/H
44
2.184
1
24.9