Gas Specifications for Non-CE Approved Dryers

***

Gas Type and

Nominal Heating Value

Supply

Pressure

**

Gross

Heat Input

Orifice Size

**

Orifice

(Injector)
Quantity

Burner

Pressure

B tu /ft

3

in WC

Btu/hr

kW

DMS

mm

in WC

Natural

1,000

7.0-13.0

55,000

16.12

20

4.089

1

3.0

*

Liquid Propane

2,500

11.0

55,000

16.12

44

2.184

1

10.0

Heat Input/Gas Consumption/Orifice (Injector) Data (For Non-CE [European] Models Only)

Shaded areas are stated in metric equivalents

*

Gas valve’s internal regulator disabled.

** Information is per pocket/tumbler.
*** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

Shaded areas are stated in metric equivalents

*

Gas valve’s internal regulator disabled.

** Information is per pocket/tumbler.
*** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)

NOTES _____________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

Gas Specifications for CE Approved Dryers

***

Gas Type and

Nominal Heating Value

Supply

Pressure

**

Gross

Heat Input

**

Fuel

Consumption

Orifice Size

**

Orifice

(Injector)

Quantity

Burner

Pressure

B tu /ft

3

mb

Btu/hr

kW

DMS

mm

mb

Natural (I

2H

/I

2E

)

1,000

15-30

55,000

16.12

1.557 M

3

/H

22

3.988

1

6.9

Natural (I

2L

)

830

20-35

55,000

16.12

1.876 M

3

/H

22

3.988

1

9.5

Natural (I

2 E L L

)

830

15-30

55,000

16.12

1.876 M

3

/H

22

3.988

1

9.5

*

Natural (I

2E+

)

1,000

20

55,000

16.12

1.557 M

3

/H

31

3.048

1

830

25

55,000

16.12

1.876 M

3

/H

31

3.048

1

*

Butane (I

3+

)

3,175

28-30

55,000

16.12

1.162 kg/H

48

1.930

1

*

Propane (I

3+

)

2,500

37

55,000

16.12

1.162 kg/H

48

1.930

1

Butane (I

3B/P

)

3,175

28-30/50

55,000

16.12

1.162 kg/H

44

2.184

1

18.1

Propane (I

3P

)

2,500

28-30/50

55,000

16.12

1.162 kg/H

44

2.184

1

24.9

Advertising