Rj-45 connector and port pin layout, Fiber optic port specifications, Rj-45 twisted- pair port pinouts – Allied Telesis AT-MC102XLPCI User Manual
Page 39

AT-MC102XLPCI 100Mbps Media Converter Installation Guide
39
RJ-45 Twisted-
Pair Port Pinouts
Figure 13 illustrates the pin layout to an RJ-45 connector and port.
Figure 13. RJ-45 Connector and Port Pin Layout
Table 6 lists the MDI and MDI-X RJ-45 pin signals with a twisted-pair port.
Fiber Optic Port Specifications
The cable requirements of the fiber
port are given in Table 7.
The fiber optic specifications are given in the following tables:
❒
Table 8, “Fiber Optic Launch Power” on page 40.
❒
Table 9, “Fiber Optic Receive Power” on page 40.
❒
Table 10, “Fiber Optic Cable Distance” on page 40.
❒
Table 11, “Fiber Optic Loss Specifications” on page 41.
Table 6. RJ-45 Pin Signals for MDI and MDI-X
Pin
MDI Signal
MDI-X Signal
1
TX+
RX+
2
TX-
RX-
3
RX+
TX+
6
RX-
TX-
Table 7. Fiber Optic Cable Loss Budget
Type of Fiber Optic Cable
Maximum
Operating
Distance
Maximum
Allowable Loss
Budget
50/125 or 62.5/125 micron
multimode
2 km (1.2
mi)
13 dB at 1310
nm