Selecting a site – Allied Telesis AT-8600 Series Switch User Manual

Page 6

Advertising
background image

Installation & Safety Guide

5

Selecting a Site

Before you install the switch, review the following considerations about its
location.

■

The switch requires an ambient temperature range of 0 º C to 40º C
(32º F to 104º F).

■

There should be adequate airflow around the switch and its vents.

■

The site should be dust-free and without moisture.

■

Humidity can be from 5% to 80% non-condensing.

■

You need a reliable and earthed (grounded) power supply source, preferably
dedicated and filtered.

■

Cabling must not be exposed to sources of electrical noise, such as radio
transmitters, broadband amplifiers, power lines, electric motors, and
fluorescent fixtures.

■

Switch ports are suitable for connection to intra-building or non-exposed
cabling is required.

■

Related network devices can be connected to the switch but cannot exceed
maximum cable lengths specified in the Hardware Reference.

■

You may need to remove cabinet doors to accommodate cords and cables.

■

Ensure easy access to the switch’s power and cable connections.