At-sb4161 & 2 switchblade power supply units – Allied Telesis SwitchBlade 4000 Series Switch Hardware Reference User Manual

Page 19

Advertising
background image

Hardware Reference

19

C613-03060-00 REV H

Mounting System

•

19 inch rack mounting

•

Front rack-mounting brackets incorporated in chassis. Mid or rear
mounting brackets optional

Expansion Bays

•

Two switch controller bays

•

Four line card bays

•

Two power supply bays

•

One fan tray bay (compatible with the AT-SB4151 fan tray)

Alarm Relays

•

Two relays on rear panel

•

Normally open and normally closed contacts

•

Software configurable for a range of conditions

•

See “Alarm Relays and Monitoring” on page 32 for more information

Backplane Links and Bus Connections

•

A SwitchBlade chassis contains two controller bays each capable of
housing a switch controller card. See “Switching Performance and
Characteristics” on page 10 for mor
e information.

•

33 MHz 64 bit PCI routing and control bus links all switch controller
and line card bays. This bus provides a high performance
communication channel between switch controller CPUs, and also
allows high speed routing between line cards that have WAN
interfaces.

Earth/Ground Point

•

An earth/ground point is provided on the chassis’s rear panel. This
point can be used to bond the chassis to earth/ground. Even if this point
is used, earth/ground leads of AC and DC power supplies must still be
connected.

AT-SB4161 & 2 SwitchBlade Power Supply Units

For guidelines on how many PSUs are required for a particular configuration,
see “How Many PSUs do You Need?” on page 33.

LEDs

•

Three LEDs indicate power supply status (input, output, and fan status)

•

For a complete list of LEDs and their functions, see “LEDs and What
They Mean” on page 47

Power Supply Specifications

Weight

•

3.6 kg