AT-MC1008 Series Installation Guide
59
To clean a recessed ferrule using a swab, perform the following procedure.
1. Insert the swab into the adapter as shown in Figure 30. Rub the
ferrule tip with the swab.
Figure 30. Cleaning a Recessed Ferrule
2. If desired, repeat step 1.
3. If a fiber inspection scope is available, use the scope to inspect the
connector to make sure that it is clean and to check for scratches,
pits, or other problems that may affect performance.
Note
Always keep a dust cap on a fiber optic cable when it is not in use.
Warning
Do not look directly at the cable or inspect the cable ends with an
optical lens when the cable is connected at the other end.