7.0 Programming Reference Sheets

--- To enter Programming, press Mode: 7 7 6 4, Enter

❑

00

❑

01

❑

02

❑

03

❑

04

❑

05

❑

06

❑

07

❑

08

❑

09

❑

10

❑

11

❑

12

❑

13

❑

14

❑

15

Addresses 00 to 15 store the Primary Phone Number. Enter 'F' to represent the end of the number.

❑

16

Primary Comm Format:

Enter 0 - F.

❑

17

❑

18

❑

19

❑

20

Primary Account Code: Valid keys are 0-F.

❑

21

❑

22

❑

23

❑

24

Primary 24-Hour Test Time.

Enter military time (i.e. 1400 for 2 PM).

❑

25

Primary Number Test Time Interval. Enter '0' for 24-hour; '1' - 12-hour.

❑

26

❑

27

❑

28

❑

29

❑

30

❑

31

❑

32

❑

33

❑

34

❑

35

❑

36

❑

37

❑

38

❑

39

❑

40

❑

41

Addresses 26-41 store the Secondary Phone Number.

Enter 'F' to represent the end of the number.

❑

42

Secondary Comm Format: Enter 0-F.

❑

43

❑

44

❑

45

❑

46

Secondary Account Code: Valid keys are 0-F.

❑

47

❑

48

❑

49

❑

50

Secondary 24-Hour Test Time.

Enter military time (i.e. 1400 for 2 PM).

❑

51

Secondary Number Test Time Interval. Enter '0' for 24-hour; '1' - 12-hour.

❑

52

❑

53

Start Monitoring Address. Valid entries are 01 through 32.

❑

54

❑

55

End Monitoring Address. Valid entries are 01 through 32.

❑

56

ADT-UDACT Communication Selection. Enter '0' to disable ADT-UDACT communication; '1' for zone

reporting receive only communication; '2' for zone reporting receive/transmit communication; '3' for point
reporting receive only; or '4' for point reporting receive/transmit.

❑

57

Backup Reporting. Enter '0' to have secondary phone number act as backup only; '1' to have secondary

phone number receive all reports and messages along with primary phone number.

❑

58

Touchtone/Rotary Select. Enter '0' for touchtone dialing; '1' for rotary dialing.

❑

59

Make/Break Ratio. If rotary dialing is selected in Address 58; Enter '0' for a 67/73 make/break ratio; '1'

for a 62/38 make/break ratio.

❑

60

Leave default of 0.

❑

61

Leave default of 0.

❑

62

AC Loss Reporting Delay. Enter '0' for no time delay after AC loss; '1' for 6 hour delay; '2' for 7 hour

delay; '3' for 8 hour delay; '4' for 9 hour delay; '5' for 10 hour delay; '6' for 11 hour delay; '7' for 15 hour
delay; '8' for 16 hour delay; '9' for 17 hour delay; 'A' for 18 hour delay; 'B' for 19 hour delay; 'C' for 20
hour delay; 'D' for 21 hour delay; 'E' for 22 hour delay; or 'F' for 23 hour delay.

❑

63

Host Panel ID. Enter '7' for Unimode 2020/1010 and ADT-MNNA; '8' for Unimode 300/400; all other

entries are invalid.

❑

64

❑

65

Loop Number. Factory set to '00'. Valid entries are 00 through 97

❑

66

❑

67

❑

68

Device/Zone Number for General Reports. Factory set to '000'. Valid entries are 000

through 999.