Agent menu – Allied Telesis AT-VIEW PLUS 3.2 DEVICE MANAGEMENT User Manual
Page 167

Allied Telesyn
AT-VIEW PLUS
DEVICE MANAGEMENT
AT-8848
Device Manager LEDs for AT-8800 Series
LED
State
Description
PWR
Green
Red
The switch is receiving power from the main power supply.
Main power supply is either off or has failed.
RPS
Green
Red
Gray
The switch is receiving power from the redundant power supply.
RPS has failed.
RPS is not installed or RPS monitoring is disabled.
DUPLEX Green
Orange
Grey
The port is operating at full duplex.
The port is operating at half duplex.
There is no link over the port.
Note
- To turn RPS monitoring on or off on the switch, from the switch command line interface
enter the command SET SYSTEM RPSMONITOR={ON|OFF}. To see whether RPS monitoring
is on, use the command SHOW SYSTEM. To turn on RPS monitoring using SNMP, set the
fanAndPsRpsMonitoringStatus variable to on.
Agent Menu
From the Agent menu, you can view and edit the system information for the switch, or log into
the CLI using Telnet.
PN 613-50665-00 Rev C