Leds on the ar725 and ar745 – Allied Telesis AR700 Series Router User Manual
Page 14

AR700 Series Router
14
LEDs on the AR725 and AR745
LED
State
Function
Power/PWR
Lit
Power is supplied and the router is switched on.
Run
Lit
The internal processor is executing code.
Off
The processor has stopped, usually a fault.
System/SYS
Off
Normal operation.
Lit
Lit briefly during router start up, or the router is
malfunctioning.
1 Flash
A router fan has failed.
2 Flashes
If RPS monitoring is enabled, and an RPS is
connected, the RPS fan has failed.
3 Flashes
If an RPS is connected, the router’s PSU (Power
Supply Unit) has failed.
4 Flashes
If RPS monitoring is enabled, the RPS PSU has
failed.
5 Flashes
If RPS monitoring is enabled, an RPS is not
connected or is not operational
Clear/CLR
Lit
A secure router has enabled PPP interfaces or
Frame Relay circuits that are configured to send
clear text.
Security/SEC
Lit
A user is logged in with security officer privilege
and the router is in security mode.
ACT
Lit
A Mini Accelerator Card (MAC) or PCI
Accelerator Card (PAC) is installed.
ERR
Lit
An error in data transmission to or from a PAC.