NHR-3TS Sub station

4. MOUNTING

Ⅵ 2-gang semi-flush mounting (NH-1SA, NH-2SA, NHR-SP, NHR-3TS)

The sub station flush-mounts in 2-gang box (UL Listed). Cover clicks to attach.
As shown terminate connector wires to the Trunk line with wire nuts, and plug into the socket.

Ⅵ Sub trunk line cabling

It is recommended to use a junction box to divide 3P trunk line to each Sub station.
Splice three cables together, i.e. Trunk line in & out cables and the cable going to the Sub at the Single-
gang box of Corridor lamp or 2-gang box for NHR-3TS.

Wire nuts

Extension
cable

6-pin plug

To: CN1
on sub
(any)

To:3P sub
trunk line

Splice 2 wires with wire-nuts,
securely protecting from being
pulled or crushed.

e

Corridor lamp (for bedside sub)

Cover

Screws(4)

2-gang box
Box must be more than 2" (50mm) deep.

3-5/16"
(83.5mm)

(NH-2SA/A in this illustration)

SINGLE-GANG-BOX
for corridor lamp

3P sub trunk
outgoing cable

3P sub trunk
incoming cable

Separate cable for
lamp (3 cond.)

Splice three cables
together with wire nuts.

To: NH-1SA or NH-2SA
bedside sub station

NHR-3TS

3P sub trunk
outgoing cable

3P sub trunk
incoming cable

Splice three cables
together with wire nut

6 lead-wires from
6-pin connector

(2-gang box)

- CAUTION: THE TOTAL SYSTEM CHASSIS RISK CURRENT SHOULD NOT EXCEED 500µA.

- ATTENTION: LE COURANT DE RISQUE TOTAL ADMISSIBLE AU CHASSIS NE DOIT PAS

DEPASSER 500µA.

Sub station back case dimensions (in recess);

NH-1SA/A,
NH-2SA/A
NHR-3TS

H

W

D

68.5

86.5

35

68.5

86.5

45

H

W

D

2-11/16" 3-7/16" 1-3/8"

2-11/16" 3-7/16" 1-3/4"