1 alarm table tab – Allied Telesis AT-VIEW PLUS 2.3 DEVICE MANAGER User Manual
Page 109
Advertising

Allied Telesyn
AT-VIEW PLUS
DEVICE MANAGER
PN 613-50504-00 Rev C
Page 109 of 121
RMON Alarm Table tab
7.4.1 Alarm Table Tab
The Alarm Table shows the list of currently defined alarm entries.
Index
The index number used to identify this alarm entry.
Sampling Interval
The time interval at which the RMON agent samples data.
Sampling MIB Variable Name
MIB variable to be monitored. The object type must be one of INTEGER, COUNTER,
GAUGE and TIMETICKS.
Sampling Type
How to compare the sampled value with the threshold. "absolute value" means comparing the
sampled data with the threshold without modification. "delta value" means comparing the
difference between the latest sampled value and the previous sampled value with the
threshold.
Advertising